|
Other manuals for this model:
manual abstract
A live camera image from the connected camera will be displayed and the camera angle can be set. Important • Access to one camera is restricted to 30 minutes. The Camera Angle Setting Tool will be disconnected automatically after 30 minutes. Reconnect if you do not complete camera angle settings within this time. • One camera cannot be accessed by the Camera Angle Setting Tool from multiple PCs at the same time. Setting the Camera Angle Connecting with a Camera List The following explains the operations for loading a camera specification file into the Camera Angle Setting Tool and using the camera list to connect to cameras. See “Creating a Camera Specification File” (P. 3-8) for information on how to create a camera specification file. • Loading a Camera Specification File 1 Click [Select Camera] from the [File] menu. The [Select Camera] dialog box will appear. 2 Double-click [Load camera specification file]. 3 Select the camera specification file and click [Open]. 3 Camera Setting 3-3 The camera specification file will be loaded and camera names listed will be displayed under [Camera List]. The camera specification file will be loaded and camera names listed will be displayed under [Camera List]. Camera list Note • The [Select Camera] dialog box will remain open unless the Camera Angle Setting Tool is shut down or the X at the top right of the dialog box is clicked. • The camera list is discarded when the Camera Angle Setting Tool is shut down. Load the camera specification file the next time you launch the Camera Angle Setting Tool. • Connecting to the Camera From the camera list, select the camera to connect to and click [Connect]. • Connecting to the Next Camera on the List Click [Next] to disconnect the camera currently connected and connect to the next camera on the list. Camera to be connected next Note In [Detailed Information], information for the camera selected in the camera list is displayed. Disconnecting from the Camera, Shutting Down 1 Click [Disconnect] from the [File] menu to disconnect the currently connected camera. 2 Click [Exit] from the [File] menu to shut down the Camera Angle Setting Tool. Important You must set Intelligent Function detection areas and privacy masks again after changing settings in the Camera Angle Setting Tool. Setting the Camera Angle Setting the Camera Angle VB-M600D VB-M600VE 3 62 Camera Setting VB-M700F 1 3 4 5 7 89 2 1 89 1 Image Display Area The image captured by the camera is shown. 2 [Switch Screen Size] button Switches the display screen size between “320 x 240” and “640 x 480.” The display screen size can also be selected from [Display Screen Size] from the [Display] menu. 3 Control Assist Displays dotted lines showing the range of pan operation and tilt operation. The camera angle cannot be changed to positions with no dotted lines. VB-M600D VB-M600VE 4 [Pan] button VB-M600D VB-M600VE Control the camera's pan operation. A q A a A s A d 4 5 6 8 A f A g A s 8 A f A g 5 [Tilt] button VB-M600D VB-M600VE Control the camera's tilt operation. 6 [Rotation] button VB-M600D VB-M600VE Control the camera's rotation operation. 7 [Rotation] slider VB-M600D VB-M600VE You can click on the slider or drag the knob to control the camera's rotation operation. 8 [Zoom] button The button to operate the zoom ratio. 9 [Zoom] slider The slider to operate the zoom ratio. 3-5 [Control Assist Display] selection box [Control Assist Display] selection box VB-M600D VB-M600VE d [Control Assist Correction] f [Focus] AqAa AAAg Select whether to [Enable] or [Disable] operation assist You can operate pan, tilt, rotation and zoom operations in in the image display area. VB-M600D/VB-M600VE to set a desired camera angle. [Control Button Display] selection box VB-M700F allows zoom operation only. VB-M600D VB-M600VE Select whether to [Enable] or [Disable] the [Pan] button • Set Using the Operation Buttons and Sliders and [Tilt] button in the image display area. As[Image Flip] selection box VB-M600D VB-M600VE VB-M600D VB-M600VE Select the orientation of the camera image. Click each of the [Pan], [Tilt], [Rotation] buttons to set the If [Enable] is selected, the image will be rotated 180 camera angle. Camera angle changes in orientation if the degrees. button is held down, and stops when the button is VB-M600D VB-M600VE released. When the orientation of the camera is moved by hand, Pan (horizontal movement) operation the operation assist display will not correspond with the actual camera angle. In this case, click [Control Assist Correction] to confirm the actual camera angle and Tilt (vertical movement) operation automatically correct the display position of operation assist. Operation assist correction takes about 1 minute to Rotation (angled movement) operation complete. To set rotation using the [Rotation] slider, drag the slider You can control the focus. and release the mouse button when the subject in the [Exposure Compensation] image is shown at a level angle. You can control the exposure...
Other models in this manual:Security Systems - VB-M600VE (14.57 mb)
Security Systems - VB-M700F (14.57 mb)