Activation of Quick Configuration loads settings directly into EEPROM. These settings will remain in effect until a unit is reconfigured. 1. Click Quick Configuration on the General tab, click it on the toolbar, or select it from the Commands menu. The Quick Configuration wizard appears with the Operating Mode window displayed. 2. Select the desired Operating Mode. 3. Select Broadcast (Host) for a network configuration of 2 or more transceivers on a Broadcast network. When configuring slave modems, configure a remote to talk to all remotes on the network. If host is configured first, the wizard will provide options for configuring remotes. See Broadcast Network for a more detailed explanation of Broadcast modes. IMPORTANT: All other selections are NOT applicable to Carrier CCN set ups. 4. Click OK. The Unit Settings screen appears. Broadcast Remote-to-All — Materials/equipment needed: •1 Host PC • 2 or more transceivers • 2 or more antennas • 2 or more power sources (outlet and/or surge strips) and 2 or more power supplies for transceivers • Configuration Manager software • (2 or more) RS232 cables Use the following procedure to install software and configure transceiver. 1. Install software. a. Power up Host PC. b. Insert the Configuration Manager software into the appropriate drive. c. View the contents of the drive (using Windows Explorer, My Computer etc.). d. Double-click Setup.exe. e. Follow the on screen instructions to complete the installation. 2. Connect the transceiver. a. Attach the power supply to transceiver 1. b. Plug the power supply into power source. c. Verify that LED 1 on the front panel of the transceiver blinks 3 times and remains lit. d. Attach an antenna to transceiver no. 1. e. Insert the RS-232 cable connector into the serial connector in the back of the transceiver. f. Attach the other end of this cable into the serial port on the back of the Host PC. 3. Configure transceiver no. 1. a. Select Configuration Manager from the Start menu in Windows. Log in using username: oem and password: oem. b. The Main window appears. c. Click Quick Configuration. d. Click Host to Broadcast. e. Click OK. f. Enter the information as shown in the dialog box below. See Fig. 6. g. Click Submit. 4. Generate a report (if desired). a. Click Report Generation. b. Click Close. c. Click Yes. 5. Connect and configure transceiver. a. Click Remote To All. b. Click OK to configure another unit. c. Disconnect serial connector from transceiver no. 1. (You can leave it connected to the computer.) d. Attach power supply to transceiver no. 2. e. Plug power supply into power source. f. Verify that LED 1 on the front panel of the transceiver blinks three times and remains lit. g. Attach an antenna to transceiver no. 2. h. Insert the RS-232 connector into the serial connector in the back of the transceiver. i. Insert the RS-232 connector into the serial connector in the back of the transceiver. See Fig. 7. j. Click Submit. 6 Fig. 6 — Host to Broadcast Set Up Fig. 7 — Transceiver 2 Configuration k. Repeat as necessary for more transceivers. l. Check Report Generation. m. Click Close. n. Click Cancel. o. Select Exit from the file menu. 6. View the report. a. Open Windows Explorer. b. Once in Windows Explorer, Open the following file: C:\Program Files\Configuration Manager\ RReport.txt. 7. Test Operation. Connect transceiver no. 1 to the host PC. Connect transceiver no. 2 to the loopback connector. Ensure all transceivers have power and have antennas properly connected. Run the loopback test in the Unit Testing section of this manual. Repeat with the host and each remote unit. ADVANCED CONFIGURATION The Configuration Manager is used to configure all transceivers being used in the network. The procedures in this section describe how to configure the transceiver to meet your specific needs. This section should be used in conjunction with the Typical Set Ups (Quick Start) section. See Fig. 8. To open your Configuration Management application: 1. From the Start menu in Windows, select Programs and then Configuration Manager. A splash screen appears with a Login dialog on top requesting username and password. 2. Enter the username: “oem” 3. Enter the password: “oem” NOTE: “oem” is lower case. 4. Click OK. The Main Window appears. A Tip of The Day window also appears. A new tip of the day will appear each time you open the configuration program. You can turn this off by unchecking the box. Click OK to dismiss the window. Getting Status — Status lights on the Status bar indicate the status of the control lines on the RS-232 link between the PC and the transceiver being configured. See Fig. 9 and Table 3. In addition to the status lights in the Configuration Manager, the LED’s on the stand-alone transceiver also display status. See Fig. 10. Exiting the Program — In order to exit the Configuration Manager, refer to the following. Select Exit from the File menu. NOTE: It is important to note that any changes in any tab not stored i...
Other models in this manual:Security Systems - WIRELESS TRANSCEIVER 33CNOAANT1 (478.88 kb)
Security Systems - WIRELESS TRANSCEIVER 33CNSNGMOD (478.88 kb)
Security Systems - WIRELESS TRANSCEIVER 33CNOAANT1 (478.88 kb)
Security Systems - WIRELESS TRANSCEIVER 33CNSNGMOD (478.88 kb)