Login:
Votes - 5, Average rating: 3.6 ( )

User manual Gentek, model 3940300

Manafacture: Gentek
File size: 1.29 mb
File name:
Language of manual:
Free link for this manual available at the bottom of the page



manual abstract


Validating the Vented Enclosure To determine the actual face velocity at the sash opening, airflow velocity readings are taken. This should be done across the sash opening of the enclosure in accordance with the Industrial Ventilation Manual. (See Appendix E) The “average face velocity” is achieved by taking readings in two rows across the enclosure with the readings 6" from the ends and evenly spaced every 12"; the first row is 3" down from the upper sash foil and the second row is 3" up from the work surface. A total of four readings will be taken for the 2' enclosure, six readings taken for the 3' enclosure and eight readings taken for the 4' enclosure and then averaged. Refer to Chapter 2 for proper airflow volumes for your particular model. The XPert enclosures have been tested at Labconco’s airflow test facility per ASHRAE 110-1995. All enclosures achieve an “as manufactured rating” of less than 0.05 part per million (ppm) at 4 liters per minute (lpm); AM <0.05 (Consult Labconco for XPert Filtered Balance System Only 21 Chapter 3: Getting Started individual ratings). For “field use” ASHRAE testing contact Labconco for a certified on-site contractor. For particulate powder validation, Labconco had containment testing performed to validate the enclosures for sodium naproxen powders. The XPert HEPA filtered enclosures demonstrated excellent containment when used by an operator using excellent technique and good containment when used by an operator using marginal technique. While no enclosure can compensate for improper technique, these tests confirm that the XPert HEPA Filtered Enclosures provide a safe working environment. Labconco also performed extensive ASHRAE testing to validate the enclosures for gas containment. For copies of these validation reports, contact Labconco Customer Service. The XPert enclosures were also subjected to Biological Containment testing, using a modified Personnel Protection Test, as described in NSF/ANSI Standard Number 49. An aerosol challenge of approximately 5 x 108 spores of Bacillus subtilus var Niger were released in the enclosure and appropriate air sampling equipment established the number of spores that escaped through the sash opening. Each size enclosure was tested three times. All three sizes of the enclosure were tested at 75 FPM inflow and typically 1 or less than one spore escaped from the enclosure during each of the tests. ! NOTE: Face velocity profiles and smoke testing should be performed frequently per your organization’s quality system to ensure safe performance. Sealing the Filtered Enclosure tothe Work Surface When the filtered enclosure has been set in place, ducted, (if necessary), and wired, it may be sealed at the work surface to prevent spilled materials from collecting under the walls. A bead of silicone sealant is recommended to seal the filtered enclosure to the work surface. 22 C CCH HHA AAP PPT TTE EER RR 4 44 H HHI IIG GGH HH P PPE EER RRF FFO OOR RRM MMA AAN NNC...

Other models in this manual:
Scales - 3940322 (1.29 mb)
Scales - 3940200 (1.29 mb)
Scales - 3940201 (1.29 mb)
Scales - 3940202 (1.29 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category