manual abstract
These words are used with the safety- --alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. UNIT OPERATION ERV with OneToucht Control INTERMITTENTMAXMIN A07625 Press “PUSH” until the desired ventilation operation is selected. There are three selections: High, Low, Intermittent. The power indicator light indicates which mode has been selected. High — This mode is recommended for the removal of excess pollutants and humidity. The ventilator will operate at its maximum speed continuously. The power indicator light will be lit red when this mode is selected. Low — This mode is recommended for normal daily operation. The ventilator will operate at its minimum speed continuously. The power indicator light will be lit yellow when this mode is selected. Intermittent — Thismode isrecommended when the insideair istoo dry in the heating season or too humid in the cooling season. Theventilator will operate at its minimum speed for 20 minutes per hour and be off for 40 minutes per hour. The power indicator light will be lit green when this mode is selected. Off — To turn the ventilator off, press “Push” until the power indicator light is turned off. ERV with Latent Control A07621 Your ERV is designed to operate as an integral part of your total heating and cooling system. Low Exchange Mode—If the relative humidity inside the building is lower than selected, air exchange would occur with the outside at high speed. If the relative humidity level inside the building is higher than selected, air exchange would occur outside at low speed. This ensures continuous air exchange for constant air quality. Intermittent Mode—If the relative humidity inside the building is higher than selected, no air exchange would occur, and the system would turn off. If the relative humidity inside the building is lower than selected, air exchange would occur with outside at high speed. Thismode isideal formaintaining theproper humidity level when the continuous mode cannot. ! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before servicing system, always turn off main power to system. Turn off accessory heater power if applicable. There may be more than 1 disconnect switch. CAUTION! PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. Although special care has been taken to minimize sharp edges in the construction of your unit, be extremely careful when handling parts or reaching into the unit. 2 MAINTENANCE BEFORE YOU REQUEST A SERVICE 1. The motors are factory lubricated. Lubricating the bearings is not recommended. 2. The core should be v...
Other models in this manual:Fans - ERVBBSVA (159.09 kb)
Fans - ERVBBSHA (159.09 kb)