(30 cm) TT 1 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Code 2 In accordance with the current CAN/CGA-B149 Installation Codes t Vent terminal shall not terminate directly above sidewalk or paved driveway located between 2 single family dwellings that serves both dwellings TT Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor and top of terminal and underside of veranda, porch, deck or balcony is greater than 1 ft (30cm) * Clearances in accordance with local installation codes and the requirements of the gas supplier Table B: Vent/Air Inlet Termination Clearances 6 WiringaPowerVentAssemblytoanAppliancewithIIDIgnitionVentingTheventpipemustbethesamesizeoronesizelarg- WARNING:Disconnectallelectricalpowertotheunitbeforeservicingtoavoidpotentialshockinjuryordamagetotheunit.Tochangevoltages,followwiringdiagramforcorrectvoltageconnections. Improperwiringconnectionscanburnouttherelayandblowermotor. 90DegreeElbows45DegreeElbowsQuantityMaximumLength(ft)QuantityMaximumLength(ft) 130135220230310325TableC:ReducedMaximumEquivalentVentRun4" DIAMETER WARNING:Disconnectallelectricalpowertotheunitbeforeservicingtoavoidpotentialshockinjuryordamagetotheunit.Tochangevoltages,followwiringdiagramforcorrectvoltageconnections. Improperwiringconnectionscanburnouttherelayandblowermotor. 90DegreeElbows45DegreeElbowsQuantityMaximumLength(ft)QuantityMaximumLength(ft) 130135220230310325TableC:ReducedMaximumEquivalentVentRun4" DIAMETER er than what is indicated. The D-2 Power Vent is capable of 360-degree discharge rotation and oper- ates with a positive vent static pressure and with a vent gas temperature less than 400°F. The total length of horizontal run shall not exceed an equiv- alent of 40 feet including termination cap. For all cases, each 90-degree elbow reduces the maximum horizontal vent run by 10 feet and each 45-degree elbow in the vent run reduces the maximum vent run by 5 feet. See the table below for maximum vent lengths using 90-degree and 45-degree elbows. The D-2 Power Vent uses positive pressure to push flue gases through the vent pipe to the outside. The vent must be installed to prevent flue gas leakage. Care must be taken during assembly to ensure that all joints are sealed properly and are airtight. The vent must be installed to prevent the potential accumulation of condensate in the vent pipes. It is rec- ommended that: a) The vent be installed with a slight downward slope of not more than 1/4” per foot of horizontal run to the vent terminal. b) The vent be insulated through the length of horizon- tal run. For appliances installed in extreme cold climate, it is recommended that: a) The vent be installed with a slight upward slope of not more than 1/4” per foot of horizontal run to the vent terminal. In this case, an approved condensate trap must be installed per applicable codes. b) The vent be insulated through the length of the hor- izontal run. LEFT SIDE Fig. 4: Draft Assembly The Raypak Power Vent operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent and as such it is listed as a CATEGORY III appliance. Exception: When a Power Vent is connected to a ver- tical vent of sufficient height to generate a negative draft in the system. Consult sizing guide or factory. The D-2 Power Vent assembly is suitable for through the wall venting, and for connection to smaller size vent pipes and breeching other than the standard atmospheric heater. 7 LEFT SIDE Fig. 5: Through the Wall Vent The D-2 Power Vent assembly includes a wire harness, shown in Fig. 6 below, which provides quick connec- tions with the respective controls in the heater control box. The harness is of sufficient length to fit the appliance for which it is sized. Reference the wiring diagram supplied with e...
Other models in this manual:Fans - 330/331 (824.36 kb)
Fans - 181/182 (824.36 kb)
Fans - 400/401 (824.36 kb)