Manafacture: GSI Outdoors
File size: 2.92 mb
File name:
|
manual abstract
The diagram details the correct main power installation for 220V 1 ph, 230V ph, 460V 3ph, 575V 3ph, and 380V 50hz power supplies. On all three phase systems put the leg with the highest potential difference between that leg and ground ( wild or high voltage leg) on the center terminal (L2) at the motor starter. NOTE: Standard electrical safety should be used. (Refer to the National Electrical Code Standard Handbook by the National Fire Protection Association). A qualified electrician should make all electrical wiring installations. Follow all local or national electrical safety standards and ordinances when installing the equipment. Main Power Schematic ELECTRICAL POWER SUPPL. 2000 Autoflo. Relay Electrical Load Dryer Fan Full Load Motor Heater Fuse Information Size Voltage Horsepower Amps Starter Strips (Slow Blow) Breaker 220v1ph 10-12 48 75 F614B 80 80 The following charts provide information for the electrician wiring the 208v3ph 10-12 35 40 C400B 60 60 grain dryer, and are a reference 36" 220v3ph 10-12 33 40 C366B 60 60 guide for parts. It is recommended 380v50hz 10-12 15 30 C180B 30 30 that you contact your local power 460v3ph 10-12 17 30 C198B 30 30 company and have a representatives survey the installation to see that 575v3ph 10-12 15 30 C180B 30 30 your wiring is compatible with their 220v1ph 10-16 78 90 F914B 100 system and that adequate power is supplied to your unit. Remember that the only thing connected to the recommended service amps should be your grain dryer. Standard electrical safety should be used. (Refer to the National Electrical Code Standard Handbook by the National Fire Protection Association). A qualified electrician should make all electrical wiring installations. 36" 208v3ph 220v3ph 380v50hz 460v3ph 575v3ph 15 15 15 15 15 44 39 27 20 16 60 60 30 30 30 C460B C400B F772B C228B C198B 60 60 60 30 30 60 60 60 30 30 42" 220v1ph 208v3ph 220v3ph 380v50hz 460v3ph 575v3ph 10-16 15 15 15 15 15 78 44 39 27 20 16 90 60 60 30 30 30 F914B C460B C400B F772B C228B C198B 100 60 60 60 30 30 100 60 60 60 30 30 42" 208v3ph 220v3ph 380v50hz 460v3ph 575v3ph 20 20 20 20 20 61 50 32 25 20 75 60 40 30 30 F772B C500B C366B C303B C228B 80 80 60 40 40 80 80 60 40 40 42" 208v3ph 220v3ph 380v50hz 460v3ph 575v3ph 30 30 30 30 30 80 74 39 37 30 90 75 40 40 40 F104C F772B C440B C400B C330B 150 150 80 80 80 150 150 80 80 80 42" 208v3ph 220v3ph 380v50hz 460v3ph 575v3ph 40 40 40 40 40 108 102 47 51 40 120 120 60 60 60 F118C F118C C500B C550B C400B 200 200 100 100 100 200 200 100 100 100 2000 Autoflo. ELECTRICAL POWER SUPPL. Wire Size Information Dryer Fan Size 36" Voltage Horsepower 220v1ph 10-12 208v3ph 10-12 220v3ph 10-12 380v50hz 10-12 Copper 100' Run 6 6 6 10 Aluminium 100' Run 4 4 4 8 Copper 200' Run 4 4 4 8 Aluminium 200' Run 2 2 2 6 Copper 300' Run 2 3 3 6 Aluminium 300' Run 0 2 2 4 460v3ph 575v3ph 10-12 10-12 10 10 8 8 8 8 6 6 6 6 4 4 36" 220v1ph 208v3ph 220v3ph 380v50hz 10-16 15 15 15 4 6 6 6 2 4 4 4 2 4 4 4 0 2 2 2 1 2 3 3 00 0 2 2 460v3ph 575v3ph 15 15 10 10 8 8 8 8 4 6 6 6 3 4 42" 220v1ph 208v3ph 220v3ph 380v50hz 10-16 15 15 15 4 6 6 6 2 4 4 4 2 4 4 4 0 2 2 2 1 2 3 3 00 0 2 2 460v3ph 575v3ph 15 15 10 10 8 8 8 8 4 6 6 6 3 4 42" 208v3ph 220v3ph 380v50hz 20 20 20 4 4 6 2 2 4 4 2 4 0 0 2 1 1 3 00 0 2 460v3ph 575v3ph 20 20 10 10 8 8 6 6 4 4 4 4 2 2 42" 208v3ph 220v3ph 380v50hz 30 30 30 1 2 6 0 0 4 0 0 4 000 00 2 0000 00 3 0000 00 2 460v3ph 575v3ph 30 30 6 6 4 4 4 4 2 2 3 3 2 2 42" 208v3ph 220v3ph 380v50hz 40 40 40 1 1 6 0 0 4 00 00 4 000 000 2 0000 0000 2 0000 0000 0 460v3ph 575v3ph 40 40 6 6 4 4 4 4 2 2 2 2 0 0 ELECTRICAL POWER SUPPL. 2000 Autoflo. Fill System Control Box Electrical Load Information The following charts provide information for the electrician wiring the grain dryer, and are a reference guide for parts. It is recommended that you contact your local power company and have a representative survey the installation to see that your wiring is compatible with their system and that adequate power is supplied to your unit. Remember that the only thing connected to the recommended service amps should be your grain dryer. Standard electrical safety should be used. (Refer to the National Electrical Code Standard handbook by the National Fire Protection Association.) A qualified electrician should make all electrical wiring installations. Relay Fill System Full Load Motor Heater HP Voltage Amps Starter Strips 3 HP 220v1ph 220v3ph 380v50hz 13 7 4 30 30 30 C137B C104B C630A 460v3ph 575v3ph 4 3 30 30 C630A C630A 5 HP 220v1ph 220v3ph 380v50hz 21 12 7 30 30 30 C228B C163B C955A 460v3ph 575v3ph 6 5 30 30 C778A C630A 7.5 HP 220v1ph 220v3ph 380v50hz 32 18 11 40 30 30 C303B C228B C151B 460v3ph 575v3ph 9 7 30 30 C125B C955B Fill System HP Voltage Full Load Amps Motor Starter Relay Heater Strips 10 HP 220v1ph 220v3ph 380v50hz 42 25 14 60 30 30 C366B C303B C180B 460v3ph 575v3ph 12 9 30 30 C163B C137B 15 HP 220v1ph 220v3ph 380v50hz 64 37 21 75 40 30 F658B C400B C273B 460v3ph 575v3ph 18 14 30 30 C214B C180B 20 HP 220v3...
Other models in this manual:Fans - AUTOFLOW 2TAF (2.92 mb)
Fans - AUTOFLOW 2TF (2.92 mb)