Login:
Votes - 2, Average rating: 5 ( )

User manual Emerson, model CF2400PW00

Manafacture: Emerson
File size: 248.25 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


There are no controls supplied with the ceiling fan. Uplight Your ceiling fan is supplied with a built-in uplight in the motor housing. This uplight has a pull chain switch in the switch housing to turn it ON or OFF. A separate switch may be used to operate the uplight. This will require a three-wire (with ground) conductor cable between the ceiling and wall outlet boxes. 1. Remove the fan motor and housing assembly from the styrofoam packaging and position it so that the top of the motor is facing you. 2. Remove the hanger ball from the downrod by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 8. HANGER BALL DOWNROD SETSCREW Figure 1 PIN 3. Separate, untwist and unkink the three motor leads. Route the motor leads through the downrod and seat the downrod in the motor coupling (Figure 2). SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP HAIRPIN CLIP CLEVIS PIN MOTOR COUPLING MOTOR LEADS DOWNROD SETSCREW CLEVIS PIN Figure 2 4 4. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). (Pin and clip are supplied in loose parts bag.) The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull the hanger ball to make sure the clevis pin is properly installed. 5. Install the setscrew (supplied) in the motor coupling (Figure 2). While pulling up on the downrod, tighten It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling. WARNING ! the setscrew using the setscrew wrench (supplied). NOTE: The setscrew must be properly installed as described above, or fan wobble could result. 6. Screw two 1” threaded studs (supplied) into the motor (Figure 3). Leave approximately 7/8” of the stud extending above the motor. Coil the wires and wire connectors around the motor coupling then slide the motor cover over the downrod and rotate the cover until the threaded studs protrude. Install two lockwashers (supplied) to secure the cover to the motor. All wires and wire connectors must be enclosed under the motor cover. LOCKWASHER (2) KNURLED KNOB (2) MOTOR COUPLING MOTOR COVER 1" THREADED STUD (2) Figure 3 NOTE: Lightly snug the knurled knobs and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor. 7. Position the ceiling cover over the downrod. Be sure the cover is oriented correctly, with the large opening at the top (Figure 4). 5 8. Reinstall the hanger ball on the downrod (Figure 4) as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod. Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin in captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble. WARNING ! It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. DOWNRODCEILING COVER PINHANGER BALLSETSCREW Figure 4 9. The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. 10. Use three 10-32 x 3/8” Phillips pan head screws (supplied) and three #10 flat washers to secure the fan blade to the blade flange (Figure 5). Repeat this procedure for the remaining four blades. 10-32 x 3/8" PHILLIPS Figure 5 PAN HEAD SCREWS (3) #10 FLAT WASHERS (3) FAN BLADE BLADE FLANGE 11. Use the 10 round recessed holes in the motor hub that are marked with a “5” and install the five blade assemblies in accordance with Step 12. One side of the switch housing has been indented to allow easy access when installing the flange screws. WARNING ! To reduce the risk of personal injury, d...

Other models in this manual:
Fans - CF2400AB00 (248.25 kb)
Fans - CF24000SCK00 (248.25 kb)
Fans - CF2400BC00 (248.25 kb)
Fans - CF2400BZH00 (248.25 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category