Login:
Votes - 2, Average rating: 3 ( )

User manual Miele, model DA 216-2 EXT

Manafacture: Miele
File size: 914.86 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Any damage which may be caused by cockroaches or other vermin will not be covered by the appliance guarantee. Warning and Safety instructions Installation The distance between the top of the cooker/hob and the bottom of the cooker hood must measure at least: – 450 mm above electric hobs and cookers – 650 mm above gas hobs and cookers – 650 mm above an open grill from our range When fitted above an open grill the cooker hood must not be used in recirculation mode. For non-Miele cooking appliances maintain the safety distance as recommended by the manufacturer in their Installation and Operating instructions. If more than one appliance is fitted beneath the cooker hood and they have different minimum safety distances to the cooker hood, select the greater distance. Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders’ merchants. The appliance must not be con nected to a chimney or vent flue which is in use. Neither should it be connected to ducting which ventilates rooms with fireplaces. If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes, seek professional advice. Warning and Safety instructions Appliances with external fans When using the cooker hood in extraction mode at the same time as another heating appliance which depends on the air in the room, (e.g. gas, oil or coal fired heaters, continuous flow or other water heaters, gas cooker, gas hob or gas oven) special care must be taken, as the action of the cooker hood extracts air from the room, which these types of heater need for combustion. They could also draw exhaust air back in from chimneys or ducting in contravention of fire safety regulations. In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible. Ventilation can be maintained by air inlets which cannot be blocked, in windows, doors and outside wall vents, or by other technical measures, such as ensuring that the extractor can only be switched on when the heating appliance is switched off or vice-versa. N.B: The overall ventilation condition of the dwelling must be taken into account. If in any doubt, the advice of a competent builder or, for gas, a "Corgi" installer must be sought. If the cooker hood is operated in recirculation mode (with active charcoal filter) then the above restrictions do not apply. For appliances with an external fan motor fitted (EXT models) the connection of the two units must be made using the connection cable and the plug connectors. Make sure the correct combination of the two appliances has been selected. Separate instructions are supplied with the external fan. Disposal of your old appliance Before discarding an old ap pliance, switch off and disconnect it from the power supply. Cut off and render any plug useless. Cut off the cable directly behind the appliance to prevent misuse. This should be done by a competent person. The manufacturer cannot be held liable for damage caused by noncompliance with these Warning and Safety instructions. Description of the appliance Description of the appliance b Extension piece c Tower d Canopy e Control panel f Main switch g Recirculation grilles h Hob lighting i Grease filters j Touch control for the hob lighting k On-Off touch control for the fan l Controls to select the Fan power level m Touch control for the run-on option This control activates the run-on option. The fan is switched off automatically after either 5 or 15 minutes. n Touch control for the grease filters The indicator light above the grease filter touch control lights up when the grease filters need to be cleaned. The touch control is used: – to reset the operating hours counter after cleaning the grease filters (see "Cleaning and Care"). – to show how long the grease filter has been in use (see section on "Operation / Filter operating hours counter"). – to alter the number of hours counted by the filter operating hours counter (see section "Operation / Altering the filter operating hours counter"). o Touch control for the active charcoal filters The indicator lamp above the active charcoal filter touch control lights up when the recirculation mode active charcoal filters need to be replaced. The touch control is used: – to reset the operating hours counter after replacing the active charcoal filters (see "Cleaning and Care"). – to show how long the active charcoal filters have been in use (see section on "Operation / Filter operating hours counter"). – to alter the number of hours counted by the filter operating hours counter (see section "Operation / Altering the filter operating hours counter"). Functional description The co...

Other models in this manual:
Fans - DA 216-2 (914.86 kb)
Fans - DA 217-2 (914.86 kb)
Fans - DA 219-2 (914.86 kb)
Fans - DA 219-2 EXT (914.86 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category