Login:
Votes - 2, Average rating: 3.5 ( )

User manual Delta Electronics, model 860 D

Manafacture: Delta Electronics
File size: 574.54 kb
File name: 219500EN.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


lamp) Fan outputs (settings) to DIN 44 971 860/8609 D Setting 1 Setting 2 Setting 3 Setting 4 Exhaust air: 200 m3/h 320 m3/h 400 m3/h 520 m3/h Return air: 140 m3/h 240 m3/h 290 m3/h 360 m3/h Exhaust air system 125 mm dia. Air outlet arranged centrally above Pipe connection of 125 mm dia. for exhaust air hoses of 125 mm dia. Air outlet Draufsicht = Plan 31 Accessories/installation materials Preparing for exhaust air operation 1 wall rail (for mounting of fume extractor hood) 4 wall plugs for 8 mm, 40 mm long wood screws (for mounting of chimney retaining plate on wall and wall rail) 4 button-head wood screws, 5 x 40 to DIN 7996 2 wall plugs for 5 mm, 30 mm long wood screws (for mounting of clamping piece) 2 button-head wood screws, 6 x 30 to DIN 85 1 drilling template for appliance mounting 1 125 mm dia., 800 mm long hose 2 125 mm dia. hose clips for above 1 chimney equalizer (230 mm high) 1 chimney cover plate with air outlet grille for return air 1 chimney retaining plate 1 guide piece (T-piece) for return air operation 4 button-head 2.9 mm x 6.5 mm long sheet metal screws (for mounting of chimney retaining plate with chimney cover plate) 3 5x 60 mm screws to DIN 7996 for mounting of wall rail 3 8 x 60 mm wall plugs for wall rail The fume extractor hood is factory-supplied for commissioning in upward exhaust air mode. Prior to installation of the fume extractor hood, a hole should be arranged in the outer wall for the wall box (return/supply air) apart from mounting drillholes. ZM3 5/90 - VOA2 5/90 GB/EU VMA1 11/89 - LAÖ2 5/90 GB/EU If the kitchen fume is run out into the open air through the external wall, you need a type MKZ telescopic wall box (with exhaust and supply air) (E-No. 610899004) (from our range of special accessories). Abluft = Exhaust air Zuluft = Supply air The dimensions and position of the air outlet opening are given in the following diagram. Draufsicht = Plan Preparing the wall box (exhaust air operation) Position of exhaust air opening Special accessories Exhaust air hoses Preparing for return air operation For wall box/fume extractor hood connection, it is best to use the non-flammable exhaust air hose under E-No. 610899008 (125 mm dia.) from our range of special accessories. The fume extractor hood is used as a return air hood when no ventilation shaft or outer wall is available. For operation as a return air hood, it is necessary to install 2 active carbon filters KL600 (E-No. 610899470) for kitchen fume absorption. Active carbon filters KL600 are supplied as special accessories (for your own account). To insert the 2 carbon filters, proceed as follows: 1. Remove metal fat filter grille (Fig. ES/D) (press outwards by unlocking the locking bolts) (Fig. EW). 2. Remove both knurled screws on the motor shaft (by turning to the left), place one active carbon filter (round) on each motor and screw the knurled screws into the motor shafts. 3. Re-insert (re-engage) metal fat filter grille....

Other models in this manual:
Fans - 860 D (574.54 kb)
Fans - 860 D (574.54 kb)
Fans - 8609 D (574.54 kb)
Fans - 8609 D (574.54 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category