|
manual abstract
The blower supplies air delivery at 105 CFM at 0" H2O static pressure, 90 CFM at 0.2" H2O static pressure. The maximum operating static pressure is 0.38" H2O. The FAB-1100 has been tested and certified by CSA. Always check local building codes. The installation must comply with local regulations as well as the National Electric Code. Failure to follow these instructions could cause a fireplace malfunction resulting in possible injury and/or property damage. PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. PRELIMINARY INSPECTION Remove the blower kit from the carton and check for any damage. Check inventory: blower assembly, sleeved power cord and installation instructions. INSTALLING THE BLOWER Step 1. In most appliances the FAB-1100 blower is simply positioned against the appliance back wall, with the magnets engaging the sheetmetal rear wall to secure the blower in place. Generally access to this location is gained by the opening (or removal) of the appliance lower compartment door of louvers Figure 1. Step 2. The blower is properly positioned when it is centered against the appliance rear wall with the outlet plenums pointed upwards (Figure 2). Ensure that the blower base is firmly seated on the appliance base. Ensure that the blower is positioned against the appliance back wall. Some appliances are fitted with a blower shield preventing access to the back wall of the appliance. In this case remove the shield, place the blower, complete its installation, then replace the shield. Step 3. Route the blower sleeved power cord to a switched, standard grounded three pronged outlet mounted on the appliance internal "J" box cover plate prewired at the time of appliance installation (see page 2 of this document, Figure 3). Ensure power cord minimizes contact with hot appliance surfaces. Operate the FAB-1100 from the switch controlling power to the appliance junction box. Figure 1 Magnets Magnets Blower in Position Make Entry where No Obstructions are Present. Figure 2 Blower Base Outlet Plenums FAB-1100 Blower Note: The FAB-1100 may also be used with the PureHeat appliance and the CGI-BAY and GI-3821 gas inserts. For use with the PureHeat and CGI-BAY appliances follow the instructions in their installation documents and those found in the PHEXK and CBEK kits respectively. The FAB-1100 is installed in the GI-3821 in accordance with instructions provided with that appliance. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Factory Supplied Not Supplied with Blower Kit Blower Plug Junction Box ON/OFF Wall Switch 120Vac 60Hz} Factory Supplied Not Supplied with Blower Kit Blower Plug Junction Box ON/OFF Wall Switch 120Vac 60Hz} APPLIANCE WIRING Most appliances are fitted with an electrical "J" box that can be accessed from outside of the appliance outer wrapper at the time of installation. The following general instructions apply. WARNING: DO NOT CONFUSE BLOWER 120 VAC 60HZ WIRING CIRCUIT WITH THE APPLIANCE LOW VOLTAGE (MILLIVOLT) OPERATING CIRCUIT. CAUTI...
Other models in this manual:Blower systems - FAB-1100 (53.07 kb)