Manafacture: HP
File size: 329.21 kb
File name:

Language of manual:en

The document is loading, please wait
The document is loading, please wait


Other manuals for this model:

manual abstract


4.1 HP 8 Internal Port SAS Controller and HP Multi-Port Internal SAS Controller

Updating the adapter firmware to version 1.23.33 or later might change the target ID of
disk devices.

This occurs on rx2660, rx3600, and rx6600 servers when an Integrated RAID volume is
configured on the controller and you perform one of the following actions:
— Update the adapter firmware offline using sasflash.efi.
— Boot to an HP-UX or Ignite-UX disk containing the sasd driver from one of the following
releases, which download firmware version 1.23.33 to the adapter during boot:

B.11.23.0712

B.11.31.0712
Changing the target ID might cause physical disks, including the OS boot disk, to become
inaccessible. If some of the disks from the IR volume are inaccessible, the volume can become
degraded or fail.
NOTE:
The target ID change does not occur on systems without a RAID-1 volume. It also
does not occur on Bl860c servers with the HP Multiport SAS Controller.
For detailed information on how to avoid or correct this problem, see Updating Internal SAS
Controller Firmware to Version 1.23.33 Or Later
at:
http://docs.hp.com/en/netcom.html

Before replacing a failed disk, make note of its Device Special File (DSF) information
If you shut down a server to replace a failed disk offline, the DSF of the failed disk will not
be visible in ioscan when the server restarts. The DSF is required by the replace_tgt
command to rebuild the array with the new disk.
Corrective Action: Before you shut down the server, run ioscan and make note of the DSF
information for the failed disk.
For more information on replacing disks, see the HP 8 Internal Port SAS Controller and HP
Multi-Port Internal SAS Controller Support Guide
at:
http://docs.hp.com/en/netcom.html
4.2 AH303A PCIe SC44Ge SAS Host Bus Adapter

Virtual Partitions will not boot in multi-initiator configurations.
Virtual Partitions (vPars) using an HP StorageWorks MSA60 or MSA70 enclosure does not
boot if AH303A cards assigned to multiple virtual partitions are connected to the same JBOD.
Under the vPars I/O resource assignment rules, a host bus adapter cannot be shared among
multiple virtual partitions.
Corrective Action: None. This issue is corrected in vPars A.05.03 (B.11.31.0803).

setboot command issue on specific servers
The setboot -p/-a/-h command fails when issued on an AH303A adapter installed in
slots 3 or 4 on HP Integrity rx3600 and rx6600 systems.
Corrective Action: Install AH303A adapters in nonswitched slots. This issue is corrected in
patch PHKL_37278.
4.3 All Controllers Supported by SerialSCSI-00

Unnecessary reboot when removing the sasd driver.
If you use swremove to remove the dynamically loaded sasd driver, the Critical Resource
Analysis (CRA) can fail. This causes swremove to incorrectly reboot the system.