Login:
Votes - 0, Average rating: 0 ( )

User manual HP, model HP Converged Network Adapters (CNA)

Manafacture: HP
File size: 598.96 kb
File name:
Language of manual:enda
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract



FCoE Boot from SAN failure
Boot from SAN intermittently fails during EFI bootstrap of a FCoE device that is busy
(QXCR1001236772). The workaround is to repeat the boot process by resetting the system.
This problem has been solved in firmware version 4.1.450.6301 or later.

FlexFabric and Converged Network Adapters Must Be Disconnected From All Boot Devices
Before Flashing Latest Firmware
Integrity FlexFabric and Converged Network Adapters must be updated offline to firmware
version 3.704.356.3 for 613431-B21 and AT111A and firmware version 2.704.356.3 for
580151-B21 or later before putting in use. Additionally, the user must unload the FCOC UEFI
driver prior to performing the firmware update or the system may crash.
For additional information, please refer to HP Customer Advisory Document ID c0314831.

HP Virtual Connect FlexFabric 10Gb/24-Port Module firmware version
A fix in AR1203 exposes an issue with the HP VC FlexFabric 10Gb/24-Port Module
(QXCR1001194681) that causes fcmsutil to incorrectly display the Previous Topology as
UNINITALIZED whenever the link goes down. Please see QXCR1001194681 for more
information and the minimum firmware version required for the HP Virtual Connect FlexFabric
10Gb/24-Port Module when the fix becomes available.

Up to a total of eight NC551m and/or NC553m HBAs are supported in a BL890c i2 system.
Up to a total of 140 Fibre Channel ports, which can be any combination of CN1100E and
AT094A HBAs, are supported in a Superdome2 system.

The HP-UX boot path is lost during un-assign and re-assign of the BL8x0C i2 (Blade) profile.
The scenario that leads to this is:
1.
Create a profile and assign it to the blade. Install a SAN disk connected from HBA with
HP-UX on it.
2.
Power off the blade.
3.
Un-assign the profile from the blade.
4.
Power on the blade to EFI shell (bare-metal state).
5.
Power off the blade.
6.
Re-assign the profile back to the same blade.
7.
Power on the blade again.
At this point, the blade should be booted from HP-UX and be up and running. However, the
blade remains in Ignite-UX and waits to be re-installed again.
NOTE:
In order to reproduce the problem, a power cycle is necessary between the un-assign
and re-assign profile steps. Without the power cycle between the un-assign and re-assign
profile, the problem does not occur.

FCoE Boot From SAN for Firmware version 4.1.450.7 or higher
In a non-Virtual Connect FlexFabric configuration, a system configured with a FCoE device in
the EFI Boot Manager should be able to boot by selecting the FCoE Boot Entry. If the system
does not have a FCoE device in EFI Boot Manager, the “Set boot from SAN” controls the
FCoE boot device mapping behavior. The “Set boot from SAN” should be set to “Enable” to
allow booting from the FCoE boot device.
In a Virtual Connect FlexFabric configuration, a system with the Fibre Channel HBA boot
parameters defined on the server profile will configure the FCoE boot device in EFI. A FCoE
Boot Entry is required to boot the device from the EFI Boot Manager. If the system does not
have the Fibre Channel HBA boot parameters defined, the boot behavior is similar to a non-VC
FlexFabric configuration above. For additional information about setting the Fibre Channel
6


...

Other models in this manual:
Network Equipment - HP Fibre Channel Host Bus Adapters (598.96 kb)
Network Equipment - HP-UX 11i v3 I/O Cards (598.96 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category