manual abstract


If OK, contact water power company 2. Debris caught in impeller or discharge 2. Remove, clean and check for tightness 3. Worn or defective pump parts or 3. Replace worn parts or entire pump. Clean parts if required plugged impeller 4. Pump running backwards 4. Check rotation. (CCW from bottom) Return if CW 5. Pump not properly sized for 5. Recheck all sizing calculations to determine proper pump application 6. Check valve stuck closed or size 6. Remove and examine check valve for proper installation installed backwards and free operation 7. Shut off valve closed 7. Open valve 6 CSECAP40, CSECAP50, CSE50T For Replacement Parts or Technical Assistance, call 1-800-237-0987 Please provide following information: Address parts correspondence to: -Model number Wayne Water Systems -Serial number (if any) 101 Production Drive -Part description and number as shown in parts list Harrison, OH 45030 U.S.A. 1 2 3 4 Model CSE50T 5 Ref No. Description Part. No. Qty. 1 Mechanical switch Kit 30000-009 1 2 Power cord 31035-001 1 3 Impeller 17317-001 1 4 Volute 41027-001 1 5 Motor Assembly with Shaft Seal 8322 1 1 2 3 4 5 6 7 8 1 5 2 8 6 7 3 4 Models CSECAP40 and CSECAP50 Ref No. Description Part. No. Qty. Capacitive Water Sensor 7465 1 Power cord, 10 ft. 31035-001 1 Impeller 17317-001 1 Volute 41027-001 1 Motor Assembly with Shaft Seal 8322 1 Bracket 7434 1 Through Bolt 16836-004 1 Screw 67050-001 3 7 Operating Instructions and Parts Manual Limited Warranty Limited lifetime (one-time full replacement) for CSE50T and CSECAP50 and five years for CSECAP40 from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions. THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO A LIMITED LIFETIME FOR CSE40T AND CSECAP50 AND FIVE YEARS FOR CSECAP40 FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions. DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records. MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________ ATTACH YOUR RECEIPT HERE 8 Instructions d’Utilisation et Manuel de Pieces de Rechange CSECAP40, CSECAP50, CSE50T S’il vous plait lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de proceder a l’entretien du produit decrit. Se proteger ainsi que les autres en observant toutes les instructions de securite, sinon, il y a risque de blessure et/ou degats materiels! Conserver ces instructions comme reference. Pompe Pour Eaux Usees Description Un systeme du tout-a-l’egout comprend une pompe, un interrupteur de commande, et un reservoir pour les applications dont moins de six toilettes (modeles) se vident dans le reservoir. Le systeme est generalement regle par un interrupteur a flotteur avec une fiche dans une fiche qui accepte la fiche de la pompe et en tour se branche dans une prise de courant de 120 V. L’interrupteur a flotteur est de type a angle large, differentiel qui monte avec le niveau du liquide et met l...

Other models in this manual:
Plumbing Product - 330502-001 (2.18 mb)
Plumbing Product - CSE50T (2.18 mb)
Plumbing Product - CSECAP40 (2.18 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category