Login:
Votes - 2, Average rating: 4 ( )

User manual Wayne, model CSE50T

Manafacture: Wayne
File size: 2.18 mb
File name:
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Sewage Pump Description A sewage system consists of a pump, control switch, and a basin for use in applications where less than six toilets (units) are discharged into the basin. The system is generally controlled by a float switch with a plug-in-plug which accepts the pump plug and in turn plugs into a 120 volt outlet. The float switch is a wide angle differential switch that rises with the liquid level and turns the pump on. As the liquid level decreases the float lowers and turns the pump off. The CSECAP40 and CSECAP50 are provided with a solid-state electronic “Switch- Genius” water level control. When water is detected, the pump will start automatically. This pump is intended for use in domestic sewage lift stations. It is suitable for pumping sewage, effluent, wastewater, groundwater and other nonexplosive, noncorrosive liquids with up to 2 inch solids. Unpacking Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death. Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Notice indicates important information, that if not followed, may cause damage to equipment. SAVE THESE INSTRUCTIONS! Specifications CSE50T CSECAP40 CSECAP50 Power supply requirements Circuit requirements Motor duty Motor Horsepower Motor full load Liquid temperature range Max. operating position Dimensions Intake Discharge Cut-in level (factory set) Cut-out level (factory set) Differential Switch Power cord 120V, 60 hz 15 amps (min) Intermittent 120V, 1 Phase 1/2 12.0 40°F to 120°F 45o from vertical 14 inches x 12inches 2 inches 2 inch NPT female 19 inches 9 inches 10 inches 90o wide angle mechanical tether switch 16 gauge 3 Conductor w/plug 120V, 60 hz 15 amps (min) Intermittent 120V, 1 Phase 4/10 (CSECAP40) 1/2 (CSECAP50) 8.7 40°F to 120°F 45o from vertical 14 inches x 12inches 2 inches 2 inch NPT female 11 inches 3 inches 7 inches “Switch-Genius” capacitive water sensor 16 gauge 3 Conductor w/plug Construction Motor body material .......................Cold rolled steel Motor housing .................................Cast iron Volute ...............................................Cast iron Impeller.............................................Glass reinforced PBT Seal plate ..........................................Cast Iron Shaft seal ..........................................Mechanical Performance GALLONS PER MINUTE AT TOTAL HEAD IN FEET Model 5 10' 15' CSECAP40 90 62 23 CSECAP50, CSE50T 113 90 33 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. 330502-001 11/07© 2007 Wayne Water Systems For parts, product & service information visit Operating Instructions and Parts Manual General Safety Information CALIFORNIA PROPOSITION 65 This product or its power cord contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. GENERAL SAFETY 1. Know the pump application, limitations, and potential hazards. Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. Use pump only with liquids compatible with pump component materials. Failure to follow this warning can result in personal injury and/or property damage. 2. Make certain that the power source (electric motor) conforms to the requirements of the equipment. Disconnect power before servicing. If the power disconnect is out of sight, lock in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock! 3. Release all pressure within the system before servicing any component. 4. Drain all liquids from the system before servicing. This pump contains dielectric motor oil for lubrication and motor heat transfer. Care should be taken when disposing of this oil. Do not use this pump in ponds or fountains because the motor oil can be harmful to aquatic life. 5. Secure the...

Other models in this manual:
Plumbing Product - 330502-001 (2.18 mb)
Plumbing Product - CSECAP40 (2.18 mb)
Plumbing Product - CSECAP50 (2.18 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category