Login:
Votes - 4, Average rating: 3.5 ( )

User manual Hans Grohe, model SELECTRONIC 6067.26X

Manafacture: Hans Grohe
File size: 869.21 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Fig. 18. 3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6). 4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note:You have 5 seconds after connecting cable to begin program process. 5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19. 6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a. Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 8. Replace COVER (3). Tighten COVER SCREWS (2) firmly. 9. Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel. 10. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor, unit will flush in approximately 3 seconds. HOWTO SET DETECTION RANGE (If Required) ; Fig. 18 & 19 Fig. 19 Fig. 19a 15 1" - 2" (30mm - 50mm) BLINKING LED 6 MAXIMUM DETECTION ZONE 400mm TO 800mm (15-3/4" TO 31-1/2") BLINKING LED Fig. 18 1 2 5 3 4 5 TO P Note: The detection distance is preset and is ideal formost installations. Should an adjustment be required follow the steps below. 1. Remove FRONT PANEL (1). See Step 9 for removing front panel instructions. 2. Remove the four COVER SCREWS (2) and COVER (3) from ELECTRICAL BOX (4). Fig. 18. 3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6). 4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note:You have 5 seconds after connecting cable to begin program process. 5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19. 6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a. Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. 8. Replace COVER (3). Tighten COVER SCREWS (2) firmly. 9. Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel. 10. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the senso...

Other models in this manual:
Plumbing Product - SELECTRONIC 6065.22X (869.21 kb)
Plumbing Product - SELECTRONIC 6065.26X (869.21 kb)
Plumbing Product - SELECTRONIC 6068.22X (869.21 kb)
Plumbing Product - SELECTRONIC 6068.26X (869.21 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category