Login:
Votes - 4, Average rating: 3.5 ( )

User manual Elkay, model EDFP217RAC

Manafacture: Elkay
File size: 106.83 kb
File name: 3d124137-6578-b1b4-fd25-e2934aea11ec.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICALAND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. FIG. 1 NOTE: WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP (NOT FURNISHED) 1/4" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY FIG. 2 97705C (Rev. J - 8/07) EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217C LEGEND FIG. 3 A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED D = 1-1/4" TRAP FURNISHED COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM E = 3/8" (10mm) DIA. HOLES FOR SECURING WALL SHUT OFF BY OTHERS FOUNTAIN TO WALL B = RECOMMENDED LOCATION FOR WASTE OUTLET F = 3/8" (10mm) DIA. SLOTS FOR MOUNTING 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL HANGER TO WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET G = WALL HANGER FURNISHED LOOSE 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL NOTE: REINFORCE THE WALL IN THE SHADED AREAS. 97705C (Rev. J - 8/07) PAGE 2 EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217RAC FIG. 4 LEGEND A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED D = 1-1/4" TRAP FURNISHED COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM E = 3/8" (10mm) DIA. HOLES FOR SECURING WALL SHUT OFF BY OTHERS FOUNTAIN TO WALL B = RECOMMENDED LOCATION FOR WASTE OUTLET F = 3/8" (10mm) DIA. SLOTS FOR MOUNTING 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL HANGER TO WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET G = WALL HANGER FURNISHED LOOSE 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL NOTE: REINFORCE THE WALL IN THE SHADED AREAS. PAGE 3 97705C (Rev. J - 8/07) EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217C W/MOUNTING PLATE FIG. 5 LEGEND NOTE: A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATEDREFERENCE SEPARATE INSTALLATION COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROMINSTRUCTIONS. FOR DETAILS ON MP20 WALL SHUT OFF BY OTHERS SURFACE MOUNTING PLATE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL D = 1-1/4" TRAP FURNISHED 97705C (Rev. J - 8/07) PAGE 4 EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217RAC W/MOUNTING PLATE FIG.6 LEGEND NOTE: A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATEDREFERENCE SEPARATE INSTALLATION COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROMINSTRUCTIONS. FOR DETAILS ON MP20RA WALL SHUT OFF BY OTHERS SURFACE MOUNTING PLATE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL D = 1-1/4" TRAP FURNISHED PAGE 5 97705C (Rev. J - 8/07) EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC INSTALLATION INSTRUCTIONS 1. Wall should already be framed for the fountain using the positioning dimensions shown in Figures 3, 4, 5, or 6. Shown dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions are required for compliance with ANSI Standard A117.0. 2. Install rough-in plumbing as shown in Figures 3, 4, 5, or 6. Waste line should extend a minimum of 2" (51mm) through the back panel. Run the supply water inlet line through the back panel. Install a service stop (not provided). Turn on supply water and flush thoroughly. 3. Install back panel. EDFP217C: Place the upper edge of the panel above hanger bracket. EDFP217C W/MOUNTING PLATE: Place the upper edge of the panel above mounting plate on the wall. Slide the panel down until it engages the mounting plate. Be sure back panel is firmly engaged before releasing it. 3. Remove bottom access panel from fountain basin and save the screws. EDFP217C: Install the fountain ...

Other models in this manual:
Other Home Accessories - EDFP217C (106.83 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category