|
manual abstract
For best results replace thecartridge every 30 days. Maintenance Cleaning: Your insect killer is equipped with self-cleaning gridsand require no special maintenance other than cleaning insectdebris from the bottom of the unit. This should be done frequently using a small soft brush or blower such as a portable hairdryer, or the exhaust attachment of a vacuum cleaner. Be sure to unplug the unit before cleaning. Do not clean yourinsect killer with a water spray or the like. Bulb Replacement 1. Disconnect unit from electric source. 2. Depress latch and remove plastic bulb retainerat base of unit as shown. 3. Bulb can now be pulled down out of the uppersocket. 4. Insert replacement bulb into upper socket.. 5. Replace plastic bulb retainer and secure latch. Bulb Retainer Replacement Bulbs Model Bulb Type Flowtron Bulb BK 15D 15 watt U-shaped bulb BF-35 BK 40D 40 watt U-shaped bulb BF-190 BK 80D 40 watt U-shaped bulb(2) BF-150 N o t i c e : Ultraviolet or "black light" is invisible to the eye, and itsability to attract insects diminishes over time. Therefore, althoughthe bulb appears to be functioning it should be replaced everyseason to maintain optimal “black light” eff e c t i v e n e s s . Two Year Limited Warranty Flowtron warrants your electronic insect killer to be free from defects in materials or workmanship under normal use and service for two years from date of original purchase. All parts except for burned out bulbs, which are defective, will be repaired free of charge. Any implied warranties, including the implied warranty of merchantability are also limited in duration to the two year period from the original purchase date. The provisions of this warranty shall not apply to any Flowtron bug killer which as been subject to misuse, neglect or accident, nor which is used for a purpose for which it is not designed, or which shall have been repaired or altered in any way so as to adversely affect its performance and reliability. Service by unauthorized parties voids your warranty. Warranty covers only the original purchaser. Commercial and/or professional use is excluded from warranty coverage. Flowtron neither assumes nor authorizes any person to assume for it any other liability in connection with its product. No responsibility is assumed for any consequential damages that may result from the use of a Flowtron product, nor for damages due to accident, abuse, lack of responsible care, the affixing of any unauthorized attachment, loss of parts or subjecting this unit to any but the specified voltage. If the unit fails to operate during the warranty period, send the product, along with purchase receipt showing purchase date and description of the problem to: Flowtron Service Center, 15 Highland Avenue, Malden, MA 02148. Transportation costs for returning any defective product are the responsibility of the consumer. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Tro u bleshooting and Repair Analy s i s C a u t i o n : unplug unit before serv i c i n g P ro b l e m A.Bulbs do not light and no high voltage on grid. Possible Cause 1. No electrical power. 2. Lamp(s) not seated properly 3. Starter defective. 4. Burned-out bulb(s). C o rre c t i o n 1. Check fuse or circuit breaker. Check extension cord. 2. Check all sockets for proper seating and alignment. 3. Starter replacement by manufacturer required.. 4. Replace bulb. B.Bulbs light, but no high voltage on grid. “ M a i n t e n a n c e ” . 1. Shorted grids. 1 . Examine killing grid for material build-up. See cleaning under C.Intermittent or continuous sparking between grid rods. 2. Transformer defective. 1. Gap between grid rods is too small. 2. Replace by manufacturer required. 1. Unplug unit and adjust grids by bending back into alignment using insulated screwdriver. D.Bulb lights, but no longer attracts insects. 2. Grid clogged with foreign material. 1. Invisible blacklight output reduced due to bulb age. 2. Clean grid using an air blower. 1. Replace bulb. See bulb replacement section of owner’s manual. Any problems you encounter that are not corrected by the action recommended in this chart should be referred to the Flowtron Service Department, 781-321-2300 Flowtron Insect Killer Accessories Security Wall Bracket Security Lantern Pole Model SB 300 Model SP 200B Attractive welded steel bracket with Lantern pole has 1" diameterlocking feature to help prevent theft. steel tubing. Locking feature helps6 1/2" long with 10" extension. prevent theft. 10 feet long with 14" extension. Powerful Lures: Replacement Bulbs Mosquito Attractant – MA 1000 Yearly replacement recommended Mosquito Attractant – MA 1000-6 (six pack) to maintain maximum black light Fly Sex lure – FA 5000 output. Makes your insect killer moreeffective in eliminatingmosquitoes and flies. Flowtron Outdoor Products, 15 Highland Ave, Malden, MA 02148 • 800-343-3280 • 557 8109 Rev 6 ...
Other models in this manual:Other Home Accessories - BK-15D (108.99 kb)