User manual Desa, model Motion Sensor Light Control 5412
Manafacture: Desa File size: 259.08 kb File name: 598-1273-00.pdf
Language of manual:
|
|
|
|
Free link for this manual available at the bottom of the page
manual abstract
• Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: Mounting Bolt Plastic Hanger Rubber Plug Lamp Holders 2 Shells Cover Plate Gasket Sensor Light Control Mounting Strap 2 Wire Connectors 6 Screws 2 Flood Lamps (3 sizes included) (some versions) Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualifi ed electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. OPERATION Mode: On-Time Works: Day Night Test 5 Seconds x x Auto 1, 5, or 10 Minutes x Manual To Dawn* x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST 10 5 1 TEST ON-TIMEPut the ON-TIME switch on the bottom of the sensor in the TEST position. AUTO ON-TIME 10 5 1 TEST Put the ON-TIME switch in the 1, 5, or 10 minute position. MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second 1 Second OFF then back on to toggle between AUTO then... and MANUAL MODE. Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position. ... back on. Mode Switching Summary TEST Move ON-TIME Switch to 1, 5, or 10 minutes AUTO Flip light switch off for one second then back on* MANUAL MODE * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. © 2006 DESA Specialty Products™ 598-1273-00 INSTALLATION For easy installation, select an existing light with a wall switch for replacement. Wall Mount Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mount only: . Swing the sensor head towards the clamp screw joint. Controls Clamp Screw . Then rotate the sensor head clockwise 180° so the controls face down. Controls Controls If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. WIRE THE LIGHT CONTROL WARNING:Turn power off at the fuse or circuit breaker. . Remove the existing light fixture. . Install the mounting strap as shown using two screws that fit your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Route the Light Control’s wires through the large gasket holes. . Twist thejunction box wires and fixture wires together as shown. Secure with wire connectors. MOUNT THE LIGHT CONTROL . Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt. . Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell. White to White Black to Black Junction box ground wire to green ground screw on fi xture. Gasket Mounting Strap Mounting Bolt Rubber Plug Shell Slot . Push the Rubber Plug firmly into place. . If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. To avoid water damage and electrical shock, keep lamp holders 30° below horizontal. Keep lamps at least 1" (2.5 cm) from the Lock Nut sensor. Do not allow the lamps to block Lens the lens. . Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten. 2 598-1273-00 TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes. . Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. ON-TIME RANGE 10 5 1 TEST MIN MAX Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffi c may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 8 ft. (2.4 m) 180° 70 ft. (21 m) Maximum Range Maximum Coverage Angle The detector is most sensitive to motion across its field of view. . Loosen the clamp screw in the sensor ball joint and gently rotate the sensor. . Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the coverage area. Keep the ...
|