manual abstract


Close the water supply valve. Depress the "Flush" switch push button for 1 1/2 minutes to drain the evaporator. Flush the evaporator with hot water to melt remaining ice. Repeat step 12, to remove all traces of the cleaning solution from the evaporator. 17. Dispense all ice out of storage hopper and discard. Dispenser Section 1. Turn off main electrical power supply to machine. 2. Remove agitator assembly from storage hopper and wash and rinse it thoroughly. 3. Wash down all inside surfaces of the ice storage area including the top cover and ice drop cover with a mild detergent solution, and rinse thoroughly to remove all traces of detergent. 4. Replace agitator. 5. Remove ice chute cover as follows: A. Flex sides outward to disengage lower pins. B. Lift Ice Chute Cover to disengage upper pins. C. Lower Ice Chute Cover down out of unit. Note. it may be helpful to twist cover slightly. 6. Clean the inside of the Ice Chute and Ice Chute Cover with a mild detergent solution and rinse thoroughly to remove all t races of detergent. 7. Reverse step above to reassemble ice chute. 8. Sanitize the inside of the hopper, agitator, ice chute and the hopper and ice drop covers with a solution of (1) ounce of household bleach in two (2) gallons of water. (200 PPM). 9. Replace the hopper cover and ice drop cover. Turn on the electrical power supply. The icemaker is ready for normal operation. FOR UNITS WITH BEVERAGE SYSTEM Cold Plate 1. Carefully remove the lower front panel. 15 90846 2. Remove cold plate cover by loosening thumbscrew on the ice drop chute and lowering chute from plastic drop tube. then, remove cover by lifting slightly in front and slide forward. 3. Wash down the inside of the cold plate, tray and cover with mild detergent solution and rinse. A small, long-handled brush will be found helpful in reaching the corners. 4. Replace the cover, taking care that it is securely positioned in cold plate tray. 5. Replace ice drop chute. 6. Replace the lower front panel, carefully feeding the tubing and wires into the cabinet. Be sure not to pinch any tubing or wires between the panel and cabinet. Beverage System 1. Remove faucet spouts, wash in mild detergent, rinse and replace. 2. Disconnect electrical power to the carbonator. Shut off the water supply and close the CO2 regulator to the carbonator. 3. Disconnect the syrup tanks from the system. 4. Energize the beverage faucets to purge the remaining soda water in the system. 5. Use a clean 5 gallon tank for each of the following: A. Cleaning Tank - Fill with hot 120° - 140° F) potable water. B. Sanitation Tank - Fill with a chlorine sanitizing solution in the strength of 1 ounce of household bleach (sodium hypochlorite) to 2 gallons cold (ambient) potable water (200 PPM). 6. Repeat the following procedure on each of the unit s syrup product lines: A. Connect the cleaning tank to the syrup line to be sanitized and to the CO2 system. B. Energize the beverage faucet until the liquid dispensed is free of any syrup. C. Disconnect the cleaning tank and hook up the sanitizing tank to the syrup line and CO2 system. D. Energize the beverage faucet until the chlorine sanitizing solution is dispensed through the faucet. Flush at least two (2) cups of liquid to insure that the sanitizing solution has filled the entire length of the syrup line. Allow solution to set in line for twenty (20) minutes. E. Disconnect the sanitizing tank. Hook up the product tank to the syrup line and to the CO2 system. F. Energize the faucet to flush the sanitizing solution from the syrup line and faucet. Continue to draw on faucet until only syrup is dispensed. 7. Repeat Step 2 in reverse order to turn on the carbonator. Dispense at least (1) cup of beverage from each faucet. Check taste. Continue to flush, if needed, to obtain a satisfactory tasting drink. 90846 16 MAINTENANCE/ADJUSTMENT PROCEDURE THERMOSTAT ALTITUDE ADJUSTMENTS IMPORTANT: Adjust the bin thermostat setting only if storage hopper over fill is a problem. Bin Thermostat 1. Open the hinged service door on the upper left side panel. 2. The adjustment screw is located below the "Flush"switch on the left side of the electrical box. 3. For altitudes up to 6000 feet, turn the adjustment screw COUNTER CLOCKWISE as follows: Elevation (Feet) CCW Turn 2000 1/13 4000 1/6 6000 1/4 4. For altitudes above 6000 feet, consul the factory. CLEARING EVAPORATOR FREEZE-UP A WARNING: Tp prevent possible injury, do not stick fingers or hands into icemaker nozzle or hopper with power applied to unit. 1. Open the hinged service door on the upper left side panel. 2. Put the stop/run switch in the "stop"position. 3. Close the water supply valve to the icemaker. 4. Remove the ice drop and hopper covers. 5. Depress the "Flush"switch push button on the electrical control box and drain the evaporator. 6. Pour hot water into the evaporator ice exit opening. It will be necessary to use either a funnel or ...

Other models in this manual:
Other Kitchen Appliances - SID650A (592.22 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category