User manual Hobart, model FT900D

Manafacture: Hobart
File size: 2.69 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


6) Repeat steps 4 and 5 for each digit. a. After pressing ENTER on the fourth digit, you will immediately return to the ENTER SECURITY CODE? screen. 7) You will know you entered the code correctly if the letter in the lower left corner reads M. Refer to Machine Operation and Programming Security Levels on page 15 for more details on other letters that may appear. a. If it does not match, repeat steps 3 through 7. b. If it does match, continue to step 8. 8) Press the UP or DOWN keys repeatedly until you reach the EDIT PARAMETERS? screen. a. If you do not see this screen after scrolling all of the way through, the Security Code was not entered properly. Repeat the steps starting from 2. 9) Press the ENTER key. a. You are now in the Parameters edit menu; the display shows the first editable parameter. Navigating the Parameters Menu NOTE: The security level must be elevated to the Super Operator or higher to enter the Parameters Menu. Refer to Machine Operation and Programming Security Levels on page 15 for more details. Hobart believes that the default settings that leave the factory are suitable for the majority of kitchen operations. However, there are cases where kitchen managers may find the need to change one or more options (Parameters Menu — Table 1); the Parameters Menu allows these changes. Within the Parameters Menu, the manager (or operator, in some cases) may modify factory default settings. The menu structure and description of each option are detailed below. Please contact Hobart Service if you are uncomfortable changing any setting or are unsure of which one(s) to change. – 17 – Parameters Menu The Parameters Menu — Table 1 lists the parameter name, a short description, a list of possible values the parameter can have, the factory default value based on the specific dishwasher model and the security level required to access that parameter. PARAMETERS MENU — TABLE 1 Parameter Name Description Model Possible Values Default Value Security Required Conveyor Speed Adjusts the speed of the conveyor in feet per FT900 4 – 10 8.5 SO minute. Increasing the value can increase the FT900D 4 – 8.5 8.5 throughput of ware, but can decrease the ability FT900S 4 – 6.3 6.3 to sufficiently clean difficult items, such as food particles cooked onto pots and pans. FT900SD 4 – 6.3 6.3 Low FR Temp Enables or disables a visual alarm on the display that Enabled Disabled M Alarm indicates that Final Rinse water temperature is below the NSF required minimum of 180°F (82°C). When enabled, a message will display notifying the user of this condition. However, machine operation will not change and ware will continue to run through the machine as expected. When disabled, there will be no extra message indicating a low-temperture event; however, the temperature display will still show the current Final Rinse water temperature. or Disabled SuperOp. Access Enables or disables the SuperOperator access level. When enabled, this allows any user to modify values in the Parameters Menu that are marked as requiring only SO security without entering a password. This can be useful, for example, to allow the operator to adjust conveyor speed based on the volume of dishes entering the dish room without the need for intervention by a manager. When disabled, the only operation allowed by any user is the ability to enter the Security Code and exit the menu. No parameters are allowed to be modified. Enabled or Disabled Disabled M Change Mgr. Code Sets a new Security Code for elevating access to the Manager Level. It is recommended to change this from the default value and store the new code where all kitchen managers, but no operators, can access it. 0000 to 8888 1001 M Edit Communications Setup? Enters the Communications Setup submenu, where settings for the NAFEM Data Protocol can be changed. Please refer to Communications Setup Menu – Table 2 for more details. M Save Settings Exits the Parameters menu and returns to the main screen. SO and Exit? Any settings that were changed are saved and most become active immediately. (If one or more settings are not active immediately, a message will display indicating that you need to cycle power to make them active.) Cancel Settings and Exit? Exits the Parameters menu and returns to the main screen. Any settings that were changed are cancelled and revert back to the previous saved values. SO – 18 – Communications Setup Menu The Communications Setup Menu — Table 2 lists the parameter name, a short description, a list of possible values the parameter can have, the factory default value based on the specific dishwasher model and the security level required to access that parameter. COMMUNICATIONS SETUP MENU — TABLE 2 Parameter Name Description Possible Values Default Value Security Required NAFEM DP Baud Adjusts the baud rate of communication between the dishwasher and a NAFEM Data Protocol (NDP) Gateway (sold separately). This must match the setting in the NDP Gateway. Refer to documentation that came wit...

Other models in this manual:
Dishwashers - FT900 (2.69 mb)
Dishwashers - FT900BD (2.69 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category