Printed in USA 0 1999 -Maytag Corporation 6 915513 A . . . ..*e................... Requirements ElectricalRequirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAUTION: Disconnect electrical power before you start! This dishwasher is designed for operation on an adequately wired All electrical wiring and grounding should be done individual 120 VAC, 60 Hz in accordance with national and local codes a approved electrical circuit. * Use required fuse (15 amp) or CAUTION: To prevent accidental contact with electrical 0 comparable circuit breaker. Two connections, built-in dishwasher models must not be connected to a power wire with ground service to the source unless the dishwasher is completely enclosed, with front panels in place. dishwasher is recommended for If the back or either side of the dishwasher is exposed, a custom-made panel connection at the terminal box must be used to complete this enclosure and for grounding GroundingInstructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAUTION: To prevent the possibility of electrical shock, this dishwasher, as other electrical appliances, must be adequately grounded. It is the responsibility of the installer at the point of installation, taking into consideration local conditions and requirements This appliance must be connected to a grounded metal, permanent wiring system: or an equipment-grounding conductor must be run with the circuit conductors and con- nected to the equipment-grounding terminal or lead on the appliance. PlumbingRequirements . . . . . . ..a . . . . . . . . ..~..................................................... CAUTION: Disconnect electrical power to dishwasher before you start! Check local plumbing code for approved plumbing procedures and accessories. All plumbing should be done in accordance with national and local codes. DoorSpringAdjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..o............................... The door has two main springs, one located on each hinge. There is a slot on the right hinge that will allow for door adjustment with the access panel removed. To change door spring tension, use a l/4” hex-nut driver to either loosen or tighten the screw located on the right door spring adjustment bracket. To increase spring tension: (If door falls coo fast) Tighten screw by turning clockwise. To decrease spring tension: (If door falls too slowly) Loosen screw by turning counterclockwise. For heavy wood panels, an auxiliary booster spring kit is available. Door Spring Adjusting Screw I lbolsNecessary for Installation* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 Cutting Knife 0 Ratchet 0 3/16”,1/4”, 5/16” Sockets 0 Phillips Screwdriver 0 Standard Screwdriver 0 Wire Cutters 0 Crescent Wrench 0 Adjustable Pliers *(Not included: Tools required for 0 Level preparing the cabinet opening). Support Accessories: 0 314” UL App roved Strain Relief (provided) Water Hook-Up Kits Available: 0 2 Appropriate Sized Wire Nuts (Water line, water valve fitting, TeflonTM tape, tee valve fitting) 5’ Braided Stainless Steel Part #19950153 0 3/8” Male (N.ET.) C om p ression Elbow or Flare Elbow 5’ Copper Part #19950152 0 Thread Sealing Tape or Pipe Thread Compound Available through an authorized Maytag Parts Retailer 0 Appropriate Sized Hose Clamp NOTE: Make sure you have everything necessary (1 3 Wood Mounting Screws (provided) for proper installation before going to step 2. 0 Drain Hose Retainer (provided) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Uncrating . . . . . . . . . . . . . . . . . . @ Remove access and toe panels before beginning installation. Q Remove bolts from the crate base brackets, using 5/16” socket with ratchet. Remove crate base and discard base and packaging. Until dishwasher is permanently installed, beware of opening the door as the unit may tip forward. QL oosen front leg bolts with a crescent wrench. Adjust rear leg bolts in same manner. CAUTION: With the door open, dishwasher may tip forward if it is not secure in position to cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prepare cabinet as needed. Electrical and water facilities should enter cabinet opening on the floor, or through the back or side walls, as shown in the shaded portion of the drawing. Preferred drain outlet is shown in the lower portion of the cabinet in drawing below. CBre should cabinet opening dishwasher dimensions be taken to route plumbing away from the motor. DO NOT m...