downloaded: 5   File size: 210 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication. 2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joi

downloaded: 6   File size: 212 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula: 9 HP = (GPM X PSI) / 1450 Exploded View - P205/P206/P207/P208/P209/P210/P211 1 2 3 3 3A 3B 4 5 5A 6 6A 7 8 9 10 11 12A 121 13 13 13 13 13 13 13 1 3 3 3 3 3 3 3 3 3 3 1 6 6 6 6 6 6

downloaded: 3   File size: 163 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

0.94 Volumetric Efficiency @ 3450 RPM ...................................................... 0.87 Mechanical Efficiency @ 3450 RPM...................................................... 0.86 Consult the factory for special requirements that must be met if the pump is I to operate beyond one or more of the limits specified above. I NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 deg

downloaded: 7   File size: 212 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication. 2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joi

downloaded: 7   File size: 275 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

11oz. Crankcase Oil Capacity..................................................................................7.5 fl.oz. Extended Crankcase Oil Capacity..................................................................9.0 fl.oz. Volumetric Efficiency @ 1750 RPM..............................................................0.95 Mechanical Efficiency @ 1750 RPM.............................................................0.86 f Consult the factory for special requirements that must be met if th

downloaded: 6   File size: 212 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. P211 H CRSEPC »WER REQUIREM HENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.60 0.4 0.6 0.8 1.0 1000 1.20 0.8 1.2 1.7 2.1 1750 2.10 1.4 2.2 2.9 3.6 3000 3.30 2.3 3.4 4.6 5.7 3200 3.52 2.4 3.6 4.9 6.1 3450 3.80 2.6 3.9 5.2 6.5 intermittent duty only HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power ou

downloaded: 1   File size: 200 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

Up to 2000 PSI ......... (140 bar) Speed .............................................................. Up to 580 RPM ........ 580 RPM Inlet Pressure .................................................. Up to 29 PSI ............ (2.0 bar) Plunger Diameter ............................................ 2.55” ......................... 65mm Plunger Stroke ................................................ 2.83” ......................... 72mm Crankshaft Diameter.......................................2.76”

downloaded: 5   File size: 212 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

Temperature of Pumped Fluids..................160° F............................70° C Inlet Ports....................................................................................................(2) 1/2" BSP Discharge Ports...........................................................................................(2) 3/8" BSP Shaft Rotation......................................................Top of Pulley Towards Fluid End Crankshaft Diameter............................................0.98

downloaded: 4   File size: 127 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

2 Specifications Models P57 & P57-0011 U.S. ..................................... Metric Flow .............................................................. 1.3 GPM ............................. 5.1 Liters/min. Discharge Pressure (Continuous) ................. 5000 PSI ............................. 350 Bar Discharge Pressure (Intermittent) ................. 6525 PSI ............................. 450 Bar Max. Inlet Pressure ....................................... 145 PSI .........................

downloaded: 3   File size: 163 kb   Manafacture: Giant  
Category: Water and Air Pumps
@name

Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric m