|
manual abstract
+fan) EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: GSH140481A* / CA*F4860D6A*+ TXV / MBR2000**-1 Design Subcooling 9 ± 3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature65 75 85 95 105 115 Entering Indoor Wet Bulb TemperatureIDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1744 MBh 45.1 46.7 51.2 - 44.0 45.6 50.0 - 43.0 44.5 48.8 - 41.9 43.5 47.6 - 39.8 41.3 45.2 - 36.9 38.2 41.9 - S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 - Delta T 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 - KW 3.09 3.15 3.25 - 3.31 3.38 3.48 - 3.51 3.58 3.69 - 3.68 3.76 3.88 - 3.83 3.91 4.03 - 3.96 4.04 4.17 - AMPS 3.8 4.1 4.5 - 4.7 5.0 5.4 - 5.8 6.1 6.6 - 6.7 7.0 7.5 - 7.6 8.0 8.5 - 8.5 8.9 9.5 - HI PR 130 140 148 - 146 157 166 - 166 179 188 - 189 203 215 - 213 229 242 - 235 253 267 - LO PR 62 66 72 - 65 69 76 - 68 72 79 - 71 76 83 - 75 79 87 - 77 82 90 - 1550 MBh 43.8 45.4 49.7 - 42.7 44.3 48.5 - 41.7 43.2 47.4 - 40.7 42.2 46.2 - 38.7 40.1 43.9 - 35.8 37.1 40.7 - S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 - Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 - KW 3.07 3.13 3.22 - 3.29 3.36 3.46 - 3.48 3.56 3.66 - 3.65 3.73 3.85 - 3.80 3.88 4.00 - 3.93 4.01 4.14 - AMPS 3.7 4.0 4.4 - 4.6 4.9 5.3 - 5.7 6.0 6.4 - 6.6 6.9 7.4 - 7.5 7.8 8.4 - 8.4 8.8 9.3 - HI PR 129 138 146 - 144 155 164 - 164 177 187 - 187 201 213 - 210 226 239 - 233 250 264 - LO PR 61 65 71 - 65 69 75 - 67 71 78 - 70 75 82 - 74 79 86 - 76 81 89 - 1356 MBh 40.4 41.9 45.9 - 39.5 40.9 44.8 - 38.5 39.9 43.7 - 37.6 38.9 42.7 - 35.7 37.0 40.5 - 33.1 34.3 37.5 - S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 - Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 13 - 19 16 12 - 18 15 12 - KW 3.00 3.06 3.15 - 3.21 3.28 3.38 - 3.40 3.47 3.58 - 3.57 3.64 3.76 - 3.71 3.79 3.91 - 3.83 3.91 4.04 - AMPS 3.4 3.7 4.0 - 4.3 4.6 5.0 - 5.3 5.6 6.0 - 6.2 6.5 7.0 - 7.1 7.4 7.9 - 7.9 8.3 8.8 - HI PR 125 134 142 - 140 151 159 - 159 171 181 - 181 195 206 - 204 220 232 - 226 243 256 - LO PR 59 63 69 - 63 67 73 - 65 69 76 - 68 73 79 - 72 76 83 - 74 79 86 - 75 1744 MBh 45.8 47.2 51.1 54.8 44.8 46.1 49.9 53.6 43.7 45.0 48.7 52.3 42.6 43.9 47.5 51.0 40.5 41.7 45.1 48.5 37.5 38.6 41.8 44.9 S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.61 0.39 0.92 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.86 0.65 0.42 Delta T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 20 19 15 11 19 18 14 10 KW 3.12 3.18 3.27 3.37 3.34 3.41 3.51 3.62 3.54 3.61 3.72 3.84 3.71 3.79 3.91 4.03 3.86 3.94 4.07 4.20 3.99 4.07 4.20 4.34 AMPS 3.9 4.2 4.6 5.0 4.8 5.1 5.6 6.0 5.9 6.2 6.7 7.2 6.8 7.2 7.7 8.2 7.7 8.1 8.6 9.3 8.7 9.1 9.6 10.3 HI PR 131 141 149 156 147 159 167 175 168 180 190 199 191 205 217 226 215 231 244 254 237 255 270 281 LO PR 62 66 72 77 66 70 76 81 68 73 79 85 72 76 83 89 75 80 87 93 78 83 91 96 1550 MBh 44.5 45.8 49.6 53.2 43.5 44.8 48.4 52.0 42.4 43.7 47.3 50.8 41.4 42.6 46.1 49.5 39.3 40.5 43.8 47.0 36.4 37.5 40.6 43.6 S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40 Delta T 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 KW 3.09 3.15 3.25 3.34 3.31 3.38 3.48 3.59 3.51 3.58 3.69 3.81 3.68 3.76 3.88 4.00 3.83 3.91 4.03 4.16 3.96 4.04 4.17 4.31 AMPS 3.8 4.1 4.5 4.9 4.7 5.0 5.4 5.9 5.8 6.1 6.6 7.1 6.7 7.0 7.5 8.1 7.6 8.0 8.5 9.1 8.5 8.9 9.5 10.1 HI PR 130 140 148 154 146 157 166 173 166 179 189 197 189 203 215 224 213 229 242 252 235 253 267 278 LO PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 95 1356 MBh 41.1 42.3 45.8 49.1 40.1 41.3 44.7 48.0 39.2 40.3 43.7 46.8 38.2 39.3 42.6 45.7 36.3 37.4 40.5 43.4 33.6 34.6 37.5 40.2 S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.80 0.60 0.39 Delta T 22 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 11 KW 3.02 3.08 3.17 3.27 3.24 3.30 3.40 3.51 3.43 3.50 3.61 3.72 3.60 3.67 3.79 3.90 3.74 3.82 3.94 4.06 3.86 3.94 4.07 4.20 AMPS 3.5 3.8 4.1 4.6 4.4 4.7 5.1 5.6 5.4 5.7 6.2 6.7 6.3 6.6 7.1 7.7 7.2 7.6 8.1 8.6 8.1 8.4 9.0 9.6 HI PR 126 136 143 149 142 152 161 168 161 173 183 191 183 197 208 217 206 222 234 244 228 245 259 270 LO PR 60 64 70 74 63 67 73 78 66 70 76 81 69 73 80 85 72 77 84 89 75 80 87 93 COOLING PERFORMANCE DATA GSH140481A* Shaded area is ACCA ( TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW= Total system power AMPS=outdoor unit amps (comp. +fan) EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: GSH140481A* / CA*F4860D6A*+ TXV / MBR2000**-1 Design Subcooling 9 ± 3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature65 75 85 95 105 115 Entering Indoor Wet Bulb TemperatureIDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67...
Other models in this manual:Water and Air Pumps - GSC140601A (829.43 kb)
Water and Air Pumps - GSC140481A (829.43 kb)
Water and Air Pumps - RT6213004 (829.43 kb)
Water and Air Pumps - GSC140421A (829.43 kb)