User manual Goodman Mfg, model GSC140601A

Manafacture: Goodman Mfg
File size: 829.43 kb
File name: RT6213004.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


• All safety information must be followed as provided in the Service Manual. Models listed on page 3. GSH 14 SEER Remote Heat Pump RT6213004 April 2006 This manual is to be used by qualified HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person. TECHNICAL INFORMATION MANUAL Copyright © 2006 Goodman Manufacturing Company, L.P. ® PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. G S H Product Family S: Split System Product Type Brand Name G: Goodman (Standard Feature Set Models) S: Goodman Deluxe (High Feature Set Models) C: Condenser R-22 X: Condenser R-410A H: Heat Pump R-22 Z: Heat Pump R-410A 14 036 1 A A Major Revision Electrical 1: 208/230V/60Hz/1ph 3: 208/230V/60Hz/3ph 4: 460V/60Hz/3ph A: Initial Release Minor Revision A: Initial Release SEER SEER Rating Nominal Capacity 018: 1.5 tons 024: 2 tons 036: 3 tons 042: 3.5 tons 048: 4 tons 060: 5 tons WARNINGWARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ONLY INDIVIDUALS MEETING THE REQUIREMENTS OF AN "ENTRY LEVEL TECHNICIAN" AS SPECIFIED BY THE AIR CONDITIONING AND REFRIGERATION INSTITUTE (ARI) MAY USE THIS INFORMATION. ATTEMPTING TO INSTALL OR REPAIR THIS UNIT WITHOUT SUCH BACK GROUND MAY RESULT IN PRODUCT DAMAGE, PERSONAL INJURY OR DEATH. WARNINGWARNING PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. GSH140181A* GSH140241A* GSH140301A* GSH140361A* GSH140421A* GSH140481A* GSH140601A* * Indicates minor revision & is not used for order entry or inventory management WARNINGWARNING TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE. WARNINGWARNING DO NOT CONNECT OR USE ANY DEVICE THAT IS NOT DESIGN CERTIFIED BY GOODMAN FOR USE WITH THIS UNIT. SERIOUS PROPERTY DAMAGE, PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/OR HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF SUCH NON-APPROVED DEVICES. PRODUCT DESIGN 4 GSH14 SEER split system heat pump models are available in 1 1/2 through 5 ton sizes. They are designed for 208/230 volt single phase applications. Air is drawn through the outdoor coil by a propeller fan, and is discharged vertically out the top of the unit. No additional restriction (ductwork) shall be applied. The suction and liquid line connections are of the sweat type for field piping with refrigerant type copper. Non-back seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. This charge is for the matching evaporator coil and a 15 foot refrigerant line set. Systems should be properly sized by heat gain and loss calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space. GSH14 units use high-efficiency Copeland® scroll compressors and there are a number of design characteristics which are different from the scroll compared to the traditional reciprocating compressor. Due to their design Scroll compressors are inherently more tolerant of liquid refrigerant. GSH14 model heat pumps do not use a reversing relay to energize the reversing valve. The reversing valve is energized in the cooling cycle through the "O" terminal on the room thermostat. This unit is for outdoor installation only. Refer to minimum figure for clearances from the sides of the unit to full walls and other objects. NOTE: This unit cannot be completely enclosed. At least one side must be unrestricted. These clearances will help avoid air recirculation. If installing two or more units at the same location, allow at least 24 inches between units. If only one side is restricted (for example, against the outside wall of a house), the unit may be placed as close as 8" to that one wall. DO NOT locate the unit: * Directly under a vent termination for a gas appliance. * Within 3 feet of a clothes drier vent * Where the refreezing of defrost water would create a hazard * Where water may rise into the unit. OK! OK! A AA AA A C C C C OK! OK! OKO!K! NOT RECOMMENDED AA AA AA AA AA B B B B Model Dimensions - W x D x H GSH140181A* 29 x 29 x 34. GSH140241A* 29 x 29 x 38. GSH140301A* 29 x 29 x 38. GSH140361A* 35. x 35. x 38. GSC140421A* 35. x 35. x 38. GSC140481A* 35. x 35. x 38. GSC140601A* 35. x 35. x 38. HEAT PUMP SPECIFICATIONS GSH14[018-060]1A* GSH140181A* GSH140241A* GSH140301A...

Other models in this manual:
Water and Air Pumps - GSC140481A (829.43 kb)
Water and Air Pumps - RT6213004 (829.43 kb)
Water and Air Pumps - GSC140421A (829.43 kb)
Water and Air Pumps - GSH 14 SEER (829.43 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category