Login:
Votes - 3, Average rating: 5 ( )

User manual Hamilton Beach, model 3000 SERIES 3060

Manafacture: Hamilton Beach
File size: 384.42 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


See Mixer Operation for recommended loading sequence. If forage is piled above reel, they may be wedged against the side when started up. KUHN KNIGHT INC. 1501 West 7th Ave. Brodhead, WI 53520-0167 701 Cherry Ave. Greeley, Co. 80632 3000STOPR005810R082503 TROUBLE SHOOTING PROBLEM: MOTOR RUNS, BUT REEL AND AUGERS DO NOT TURN CAUSE SOLUTION SHEAR BOLT ON PTO DRIVELINE HAS SHEARED BELTS ARE SLIPPING BROKEN CHAIN Replace with Same Grade and size shear bolt. Do not us any bolt other than a Gr 5 see PTO driveline setup for more information. If problem persists, call Kuhn Knight Inc. Service Dept. Adjust or replace belts as outlined in “INSPECTION AND ADJUSTMENT” section. If problem persists, call Kuhn Knight Inc. Service Dept. Make sure that mixer is not overloaded. Replace broken chain. A spliced chain will not be as strong as a new chain and may break in another place. Be sure to inspect bearings, bearing mounts, and shafts for any damage caused by excessive pressure PROBLEM: SEAL LEAKING ON UPPER AUGER CAUSE SOLUTION BOLTS MAY HAVE WORKED LOOSE ON SEAL RETAINER SEAL IS DAMAGED Tighten or replace bolts Replace Seal PROBLEM: SEAL LEAKING ON INPUT SHAFT CAUSE SOLUTION OIL BATH IS OVERFILLED SEAL IS DAMAGED The oil level in the sealed drive compartment should be maintained at the “oil level” plug on the drive compartment housing. This allows the oil to be thrown onto all the other chains inside the drive compartment. Replace Seal PROBLEM: EXCESSIVE CHAIN NOISE CAUSE SOLUTION MISALIGNED SPROCKETS WORN SPROCKET AND OR CHAIN Check sprockets for worn edges of teeth. Use a straight edge to verify the alignment of the sprockets. Inspect sprockets and chains. Replace if excessively worn. PROBLEM: FEED IS SEPARATING AS IT DISCHARGES FROM THE MIXER DOOR CAUSE SOLUTION DOOR IS OPEN LESS THAN HALF WAY Hay mixed in the load will separate from the grain if the discharge door is not open at least half way. Additional flow control plates may be required. 3000STOPR005810R082503 TROUBLE SHOOTING PROBLEM: OIL LEAKING AROUND THE EDGES OF THE OIL BATH CAUSE SOLUTION INSPECT SHIELD FOR LOOSENESS DAMAGED OR LOOSE GASKET MATERIAL AROUND ENCLOSURE SHIELD Carefully tighten wing nuts or adjust locking fasteners that hold shield in place, hand tighten only. Check for foreign material between the foam gasket and shield. Remove shield and check gasket material for proper adhesion to the mating panel of mixer. If gasket adhesive has come loose from front panel, replace gasket. PROBLEM: HYDRAULIC DOOR SYSTEM OPERATES ERRATICALLY CAUSE SOLUTION COMPONENTS STICKING OR BINDING INADEQUATE FLOW OR PRESSURE FROM HYDRAULIC SYSTEM. OIL IS LEAKING PAST SEALS IN CYLINDERS OR VALVES Check for hydraulic oil contamination, dirt, or gummy deposits. If dirt is found, search and repair the source. Check for worn or bent parts. Check oil level in hydraulic system. Check fluid and fill to proper level. Install seal kits to repair worn seals. See parts listing for part numbers. PROBLEM: SCALE HANGS UP,...

Other models in this manual:
Mixers - 3000 SERIES 3015 (384.42 kb)
Mixers - 3000 SERIES 3015 (384.42 kb)
Mixers - 3000 SERIES 3020 (384.42 kb)
Mixers - 3000 SERIES 3020 (384.42 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category