Login:
Votes - 1, Average rating: 5 ( )

User manual Supra, model LAUNCH 22SSV

Manafacture: Supra
File size: 1.46 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


If the voltmeter does not register in the normal range, there may be a problem within the electrical system. It is normal for the voltmeter needle to fall when starting the engine. Normal range is 12 to 14 volts. Oil Pressure Gauge The oil pressure gauge indicates the oil pressure in the engine while the engine is running. If the oil pressure remains below the normal range of 20 to 80 psi, stop the engine immediately. If engine is allowed to run while oil pressure is too low, permanent engine damage may occur. Running the engine with low oil pressure may cause severe engine damage. © 2005 Skier’s Choice, Inc. SUPRA - 27 Depth Sounder Setting Units The depth sounder can display depth in either standard or metric units. Perform the following steps to change the display units: 1.Simultaneously press the up and down buttons. Either the FT or M units indicator display text will flash. THEN... 2.To set feet units, press the up button. The FT indicator display text will flash for five seconds and return to normal mode display with feet as the current units. OR... 3.To set Meter units, press the down button. The M indicator display text will flash for five seconds and return to normal mode display with Meters as the current units. NOTE: When power is applied or removed and reapplied, the units display defaults to feet units. Setting Deep Alarm The deep alarm function can be set for depths ranging from 3 feet (1.0 Meter) to 200 feet (60.9 Meters). An alarm triggers when the water depth is greater than the set value. Setting Deep Alarm (continued) To set the Deep Alarm, perform the following: 1.Press the down button. The current deep alarm depth setting will display. 2.Press the up or down button to increase or decrease respectively the deep alarm depth value. Pressing either button once will change the depth value in 1-foot or 0.1 Meter increments. Holding either button will change the depth value in 9-foot or 1-Meter increments per second. 3.After setting the depth value, the alarm and down arrow icons will blink for five seconds then the display will return to normal operating mode with the alarm and down arrow icons displayed. When triggered, an audible alarm sounds for ten seconds while flashing the warning LED, alarm and down icons on the display. After ten seconds, the audible alarm mutes but the LED and display icons continue to flash. NOTE: When power is removed from the instrument, all depth settings are returned to “000”. Setting Shallow Alarm The shallow alarm function can be set for depths ranging from 3 feet (1.0 Meter) to 200 feet (60.9 Meters). An alarm triggers when the water depth is less than the set value. To set the Shallow alarm, perform the following: 1.Press the up button. The current shallow alarm depth setting will display. 2.Press the up or down button to increase or decrease respectively the shallow alarm depth value. Pressing either button once will change the depth value in 1-foot or 0.1 Meter increments. Holding either button will change the depth value in 9-foot or 1-Meter increments per second. 3.After setting the depth value, the alarm and up arrow icons will blink for five seconds then the display will return to normal operating mode with the alarm and up arrow icons displayed. When triggered, an audible alarm sounds for ten seconds while flashing the warning LED, alarm and up icons on the display. After ten seconds, the audible alarm mutes but the LED and display icons continue to flash. NOTE: When power is removed from the instrument, all depth settings are returned to “000”. SUPRA - 28 © 2005 Skier’s Choice, Inc. Out of Range Display If the display indicates three horizontal bars as shown, the depth sounder indicates an out of range, inaccurate or incomplete data condition. An out of range condition occurs when the depth reading is less than 2.5 feet (3.0 Meters) or greater than 200 feet (60.9 Meters). Inaccurate or incomplete data will cause an out of range condition when operating in extremely dirty water, very soft bottom or at high speeds. A faulty or improper transducer connection can also cause an out of range error condition. Troubleshooting INSTRUMENT DOES NOT TURN ON 1.If applicable, check main power supply fuse to the unit. If it is blown, replace it with a 1 amp, normal blow fuse. If in-line fuse is used, clean all corrosion from the fuse. Troubleshooting INSTRUMENT DOES NOT TURN ON (continued) housing or replace the fuse holder assembly if necessary. 2.Check the power cable connection. Be sure that the unit is connected to a known power source: RED wire to positive, BLACK wire to negative or ground. 3.Ensure that the power source is powered using a test light or some other reliable form of testing 12 volt power. 4.If you are sure that the unit is receiving power and is still not functioning, please contact Customer Service for assistance. RANDOM OR FLASHING BOTTOM READING 1.Under certain circumstances, the depth sounder may not perform at the best of its ability. Extr...

Other models in this manual:
Boats - COMP LTS (1.46 mb)
Boats - LAUNCH 21 (1.46 mb)
Boats - LAUNCH 21V (1.46 mb)
Boats - LAUNCH 24SSV (1.46 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category