|
manual abstract
. . . . . . .2, 3 Operating Instructions . . . . . .4, 5 Additional Controls . . . . . . . . . . .5 Controls . . . . . . . . . . . . . . . . . . . .4 Normal Operating Sounds . . . . .5 Care and Cleaning Air Filter . . . . . . . . . . . . . . . . . . .6 Grille and Case . . . . . . . . . . . . . .6 Grille Frame Removal . . . . . . . . .6 Outdoor Coils . . . . . . . . . . . . . . .6 Installation Instructions Through-the-Wall Installation—Optional . . . . . . . .13 Window Installation . . . . . . . .8–12 Troubleshooting Tips . . . . . . .14 Consumer Support Consumer Support . . . . . . . . . .16 Warranty . . . . . . . . . . . . . . . . . .15 Write the model and serial numbers here: Model # __________________________ Serial # __________________________ Find these numbers on a label on the side of the air conditioner. Owner’s Manual and Installation Instructions AEE18 49-7570 02-07 JR IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock Consumer Support Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions or personal injury. SAFETY PRECAUTIONS Use this appliance only for its intended purpose as described in this Owner’s Manual. This air conditioner must be properly installed in accordance with the Installation Instructions before it is used. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle. Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end. HOW TO CONNECT ELECTRICITY Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded. DO NOT use an adapter plug with this appliance. The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance. Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician. Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning. NOTE: We strongly recommend that any servicing be performed by a qualified individual. For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate. This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires. See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements. 2 ge.com WARNING! EXTENSION CORDS—115-Volt models only Because of potential safety hazards under certain CAUTION: conditions, we strongly recommend against the use of an extension cord. DO NOT use an extension cord with any of the 230/208 volt models. However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS Consumer SupportTroubleshooting Instructions Installation 3 Consumer Support Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions About the controls on the air conditioner. Features and appearance will vary. TEMP CONTROL MODE CONTROL Temp Control The temp control is used to maintain the room temperature. The comp...
Other models in this manual:Air Conditioner & Split Systems - AEE18 (626.34 kb)