manual abstract


Save to reinstall later. Remove the ground screw and save to reinstall later. Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. G F E Remove the ground screw and save to reinstall later 3 Window Installation Instructions INSTALL THE CASE IN THE WINDOW Carefully slide the case into the window and center the case. Lower the window behind the top mounting rail. Pull the bottom of the case forward so that the bottom mounting rail is tight against the back of the window stool. Mount the case to the window sill using 4 type E screws. Drill pilot holes, if necessary. Make sure the bolts and nuts are all of the way in both the left and right V-supports. Position the V-supports on the case bottom so that they will be near the outside wall. Attach a V-support to each side of the bottom of the case using type C screws, 3 on each side. Use a wood block (obtained locally) between the leveling bolts and the wall if the wall is weak or if the weight of the air conditioner falls between the studs in the wall. Adjust the leveling bolts and nuts against the outside wall so that the case has a slight tilt to the outside. Tighten nuts with an adjustable wrench. Use a level; no more than a 1/2 bubble will be the correct case slant to the outside. E D C B A 6 INSTALL SUPPORT BRACKETS AND THE FOAM TOP WINDOW GASKET Drill pilot holes and attach the support brackets with two type D screws, one on each side. Cut the foam top window gasket to the window width. Stuff the foam between the glass and the window to prevent air and insects from getting into the room. C B A 7 11 4 type E screws Stool Bolt and nut V-support INSTALL THE CASE IN THE WINDOW (cont.) Extend the left and right accordion panels to the vertical window sashes. Drill pilot holes and attach the top and bottom corners with 4 type D screws. F 6 Type D screw Type D screw Type D screw Top mounting rail Type D screw INSTALL THE AIR CONDITIONER IN THE CASE Make sure the ground wire is off to the side and slide the air conditioner into the case. Do not push on the controls or the finned coils. Make sure the air conditioner is firmly seated. Reinstall the locking bracket and screw removed earlier. Reconnect the ground wire to the air conditioner using the screw removed earlier. IMPORTANT: The ground wire must be reinstalled to ensure a proper ground. Reattach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case. D C B A 8 Window Installation Instructions INSTALL THE AIR CONDITIONER IN THE CASE (cont.) Press the grille frame in around the power cord on the right side. Secure the grille with the painted screws on each side and the screw in the front that were removed earlier. Reinstall the filter. Reinstall the inlet grille. Connect power. Caulk or weather-strip any gaps or openings to the outside to seal the installation. G F E 8 Guide the lever carefully through the grille frame as you push it in. Screw Screw Screw 12 Through-the-Wall Installation Instructions—Optional 13 The case may be installed through-the-wall in both existing and new construction. Read completely, then follow step-by-step. NOTE: Except for the V-support assemblies (included), obtain all materials locally for mounting the air conditioner through-the-wall. IMPORTANT (cont.) Secure with 14 wood screws anchored at least an inch into the wall support structure. NOTE: Drill pilot holes, if necessary, for proper installation. If the frame is oversized, use shims to prevent case distortion. Install the V-supports. See the INSTALL THE CASE IN THE WINDOW section in the Window Installation Instructions. 1 D E IMPORTANT Through-the-wall installation is not appropriate if any of the side or top louvers in the case will be obstructed by the wall. All side and top louvers in the case must project on the outdoor side of the wall. The room side of the case must project into the room far enough to maximize the balance of the unit. The case must be installed level from side- to-side and with a slight tilt from front to rear. Use a level; no more than a 1/2 bubble will be the correct case slant to the outside. Lintel angle is required to support bricks or blocks above opening. Flashing is required and should extend the length of the opening to ensure no inside cavity leakage occurs. Remove the air conditioner from the case. For specific instruction, refer to the Window Installation Instructions. Make certain that a wall receptacle is available close to the hole location or make arrangements to install a receptacle. 1 A B FINISH THE WALL OPENING Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down the outside of the building. 2 Lintel angle Plaster line Trim molding (if desired) INSIDE Bottom rail V-supports Wood filler and caulking (above ...

Other models in this manual:
Air Conditioner & Split Systems - AEE18 (626.34 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category