Login:
Votes - 0, Average rating: 0 ( )

User manual LG, model LSNR126ABL

Manafacture: LG
File size: 3.31 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


Carefully open vertical louver to allow access to the horizontal airflow direction. Adjust the left/right airflow direction by hand. Vertical Airflow Direction Control Horizontal Airflow Direction Control (Optional) The left/right(Horizontal Airflow) can be adjusted by using the remote control. Press the Start/Stop button to start the unit. Open the door on the remote control. Press the Airflow Direction Start/Stop button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction. 15 Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips Open the front panel upward Power button ENGLISH Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button. Forced Operation Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode. Heat pump Model Cooling Model Room Temp. . 24°C 21°C . Room Temp. < 24°C Room Temp. < 21°C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22°C 22°C 23°C 24°C Helpful information Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly. High Speed Test operation During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about 3 seconds. If you want to stop the operation, re-press the button. 16Safety Precautions Troubleshooting Tips Care and Maintenance Operating Instructions Calling from outside, you can start the air conditioner to keep the room comfortable. Even though you went out with the air conditioner on, you can turn it off using the phone outside. Telephone Control Operation(Optional) Dial the number which is connected with the air conditioner. After ringing 5 times. You can hear the "Beep" sound (if the air conditioner is off), then press "0" "0" "7" "8" accordingly. With the sound "Beep, Beep" the air conditioner starts on. Hang up the phone. 1 TURN ON Dial the number which is connected with the air conditioner. After ringing 5 times. You can hear the "Beep Beep" sound (if the air conditioner is on), then press "0" "0" "7" "9" accordingly. With the sound "Beep---" the air conditioner is turned off. Hang up the phone. 2 TURN OFF Note: . This product works after telephone rings 5 times. . If internal user picks up the phone before 5 rings, Telephone control function does not work. . If user doesn't push the telephone button 25 seconds after beep, Telephone control function doesn't work. . If it is connected to key phone, it cannot be worked. OGM guide is provided after signal sound rings four times and then "Beep"(sounds from telephone itself) sounds so that outside recording can be done. Slowly press password "0" "0" "7" and "8" in order. OGM guide is provided after signal sound rings four times and then "Beep"(sounds from telephone itself) sounds so that outside recording can be done. Slowly press password "0" "0" "7" and "9" in order. . The numbers of response bell should be adjusted to four times if pressing "Out-of-office" button or taking other action for automatic response. . The recording time of OGM (Outgoing Message) should be less than approximately 15 seconds. When using along with ARS telephone When using along with ARS telephone When using along with ARS telephone ON OFFFF ON OFF 17 Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips ENGLISH CAUTION: Before performing any maintenance, turn off the main power to the system. Indoor Unit Grille, Case, and Remote Control . Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTE: Supply power must be disconnected before cleaning the indoor unit. AIR FILTERS The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary. PLASMA FILTER, DEODORIZER FILTER(OPTIONAL) The PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary. . Never use a...

Other models in this manual:
Air Conditioner & Split Systems - LSUR126ABL (3.31 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category