The temperature does not change. The cool (warm) air does not come out of the air conditioner. The fan speed does not change. Timer function does not set. Odors permeate in the room during operation. The air conditioner makes a bubbling sound. Water is dripping from the air flow blades. Remote control is not working. The air conditioner does not turn on or off with the wired remote control. The wired remote control does not operate. The indicators of the digital display flashes. SOLUTION • Because of the protective mechanism, the appliance does not start operating immediately to keep the unit from overloading. The air conditioner will start in 3 minutes. • Check that the power plug is properly connected. Insert the power plug into the wall socket correctly. • Check if the circuit breaker is switched off. • Check if there is a power failure. • Check your fuse. Make sure it is not blown out. • Check if you selected Fan mode. Press the Mode button on the remote control to select another mode. • Check if the set temperature is higher (lower) than the current temperature. Press the Temperature button on the remote control to change the set temperature. Press the Temperature button to decrease or increase the temperature. • Check if the air filter is blocked by dirt. Clean the air filter every two weeks. • Check if the air conditioner has just been turned on. If so, wait 3 minutes. Cool air does not come out to protect the compressor of the outdoor unit. • Check if the air conditioner is installed in a place with a direct exposure to sunlight. Hang curtains on windows to boost cooling efficiency. • Check if the cover or any obstacle is not near the outdoor unit. • Check if the refrigerant pipe is too long. • Check if the air conditioner is only available in Cool mode. • Check if the remote control is only available for cooling model. • Check if you selected Auto or Dry mode. The air conditioner automatically adjusts the fan speed to Auto in Auto/Dry mode. • Check if you press the Power button on the remote control after you have set the time. • Check if the appliance is running in a smoky area or if there is a smell entering from outside. Operate the air conditioner in Fan mode or open the windows to air out the room. • A bubbling sound may be heard when the refrigerant is circulating through the compressor. Let the air conditioner operate in a selected mode. • When you press the Power button on the remote control, noise may be heard from the drain pump inside the air conditioner. • Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards. Condensation may generate due to the difference in temperature. • Check if your batteries are depleted. • Make sure batteries are correctly installed. • Make sure nothing is blocking your remote control sensor. • Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves. • Check if you set the wired remote control for group control. • Check if TEST indicator is displayed on the wired remote control. If so, turn off the unit and switch off the circuit breaker. Call your nearest contact center. • Press the Power button on the remote control to turn the unit off and switch the circuit breaker off. Then, switch it on again. 18_ appendix OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR OUTDOOR COOLING 18.C to 32.C -15.C to 43.C 80% or less - - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor. Internal protection triggers and the air conditioner will stop. Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor. HEATING 27.C or less -20.C to 24.C DRYING 18.C to 32.C -15.C to 43.C The standardized temperature for heating is 7.C. If the outdoor temperature drops to 0.C or below, the heating capacity can be reduced depending on the temperature condition. If the cooling operation is used at over 32.C (indoor temperature), it does not cool at its full capacity. ENGLISH appendix _19 QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT ALBANIA 42 27 5755 AUSTRIA "0810 - SAMSUNG (7267864, € 0.07/min)" BELGIUM 02-201-24-18 "(Dutch) (French)" BOSNIA 05 133 1999 BULGARIA 07001 33 11 CROATIA 062 SAMSUNG (062 726 7864) CZECH 800 - SAMSUNG (800-726786) DENMARK 70 70 19 70 FINLAND 030 - 6227 515 FRANCE 01 48 63 00 00 GERMANY 01805 - SAMSUNG(726-7864 € 0,14/Min) GREECE "IT and Mobile : 80111-SAMSUNG (80111 7267864) from land line, local charge/ from mobile, 210 6897691 Cameras...
Other models in this manual:Air Conditioner & Split Systems - AC052FBCDEH (1.58 mb)
Air Conditioner & Split Systems - FH052EAV1 (1.58 mb)