Login:
Votes - 4, Average rating: 4.5 ( )

User manual Kenmore, model CS-E24JKR

Manafacture: Kenmore
File size: 1.84 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


, Not used in normal operations. Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. POWERFULQUIETMILD DRY COOLING ECONOMY TO SET THE TIMERTO SET THE TIMER • 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time. Select ON or OFF Timer Set the time. Confirm. TIMER• Example of application at living room: Morning: ON ..1 at 07:00 (Wake up) OFF ..1 at 08:00 (Out for work) Evening: ON ..2 at 17:00 (Back home) OFF ..2 at 22:00 (Sleep) • To cancel ON or OFF timer, press or to select respective ..1 or ..2 then press . • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing or to select respective ..1 or ..2 then press . • Upcoming timer will be displayed and will be activated in sequence. • When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. Cancel..2..1Cancel..2..1 Cancel..2..1Cancel..2..1 • , ECONOMY and QUIET/ POWERFUL can be activated in all modes and can be cancelled by pressing therespective button again. • MILD DRY only can be activated in COOL mode and can be cancelled by pressing the button again. • MILD DRY , ECONOMY and QUIET/ POWERFUL cannot be activated at the same time. • can be activated even when the unit is turned off. In this condition, once e-ion operation is ON, theunit will operate with AUTO fan speed and air swing. TO SELECT FAN SPEED (5 OPTIONS) • For AUTO, the indoor fan speed is automaticallyadjusted according to the operation mode. AIR SWING TO ADJUST AIRFLOW DIRECTION (5 OPTIONS) • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set, the louver swingleft/right and up/down automatically. • In HEAT mode, if AUTO is set, the horizontal louver fix at predetermined position. The vertical louver swingleft/right after the temperature rises. TO MONITOR AIR QUALITY• Patrol sensor detects air quality. • When air quality is unsatisfactory, e-ion operation willstart automatically. ECONOMY TO SAVE ELECTRICAL POWER CONSUMPTION • Save power consumption at unoccupied room byadjust set temperature up to 3°C automatically. • Brightness of all indicators will be dimmed. QUIET/ POWERFUL POWERFUL NORMALQUIET TO ENJOY QUIET ENVIRONMENT • This operation reduces indoor andoutdoor units noise. TO ACHIEVE TEMPERATURE QUICKLY• This operation will stop automaticallyafter 20 minutes. MILD DRY TO IMPROVE HUMIDITY AND MOISTURE LEVEL • This operation reduces air dryness and provides youwith a comfortable living environment. • When vertical airflow direction is set to AUTO, itstops at lower position to avoid cold air contact. However, you can adjust the louver directionmanually. OPTIONAL SETTINGSOPTIONAL SETTINGS Patrol starts automatically with the unit switched on with . Press and hold for 5 seconds, then release to disable or restore this setting. Press and hold for 5 seconds to dim or restore the unit’s indicator brightness. Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press to restore the remote control’s default setting. , Not used in normal operations. Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. POWERFULQUIETMILD DRY COOLING ECONOMY TO SET THE TIMERTO SET THE TIMER • 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time. Select ON or OFF Timer Set the time. Confirm. TIMER• Example of application at living room: Morning: ON ..1 at 07:00 (Wake up) OFF ..1 at 08:00 (Out for work) Evening: ON ..2 at 17:00 (Back home) OFF ..2 at 22:00 (Sleep) • To cancel ON or OFF timer, press or to select respective ..1 or ..2 then press . • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing or to select respective ..1 or ..2 then press . • Upcoming timer will be displayed and will be activated in sequence. • When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. Cancel..2..1Cancel..2..1 Cancel..2..1Cancel..2..1 6 CAREE & CLLEEANIING • Switch off the power supply before cleaning. • Do not touch the aluminium fi n, sharp parts may cause injury. CAUTION Remove • Do not use benzene, thinner or scouring powder. • Use only soap ( pH7) or neutral household detergent. • Do not use water hotter than 40°C. HINT • To ensure optimal performance of the unit, cleaning maintenance have to be carried out at regular intervals. Dirty unit may caused malfunction and you may retrieve error code “H99”. Please co...

Other models in this manual:
Air Conditioner & Split Systems - CS-E21JKR (1.84 mb)
Air Conditioner & Split Systems - CS-E18JKR (1.84 mb)
Air Conditioner & Split Systems - CS-E28JKR (1.84 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category