Be sure the Intake Grille (Fig. 4 9) is installed securely. When removing and replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result. CAUTION! Cleaning the Air Filter 1. Open the Intake Grille, and remove the air filter. Lift up the air filter’s handle, disconnect the two lower tabs, and pull out. 2. Remove dust with a vacuum cleaner or by washing. After washing, allow to dry thoroughly in a shaded place. 3. Replace the Air Filter and close the Intake Grille. 1 Align the sides of the air filter with the panel, and push in fully, making sure the two lower tabs are returned properly to their holes in the panel. 2 Close the Intake Grille. (For purposes of example, the illustration shows the unit without Intake Grille installed.) Dust can be cleaned from the air filter either with a vacuum cleaner, or by washing the filter in a solution of mild detergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before reinstalling. If dirt is allowed to accumulate on the air filter, air flow will be reduced, lowering operating efficiency and increasing noise. During periods of normal use, the Air Filters should be cleaned every two weeks. When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel. When cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner. Do not expose the unit body to liquid insecticides or hairsprays. When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half day to allow internal parts to dry thoroughly. Intake Grille Air filter handle Intake Grille Intake Grille Mounting shaft Knob Intake Grille Bearing Mounting shaft Knob Mounting shaft Knob En-13 CLEANING THE PLASMA AIR CLEANING FILTER CAUTION! WARNING! Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks on it. If the unit is not properly mounted, it could fall off and cause damage or injury. You can be injured if you touch the heat exchanger when removing or installing the plasma filter unit. Do not insert your fingers between the plasma filter unit and the heat exchanger. Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner. Electric shock may result. Regarding the Air Cleaning check function This function is illustrated by the flashing of the AIR CLEAN Indicator Lamp (green), indicating that the unit requires maintenance. After Air Cleaning Mode has been in use for approximately 400 hours, the AIR CLEAN Indicator Lamp (green) will begin to slowly flash (approximately once every 7 seconds). When this occurs, the unit requires maintenance. After Air Cleaning Mode has been in use for approximately 500 hours, the AIR CLEAN Indicator Lamp (green) will begin to flash quickly (approximately once every 3 seconds). At this point, Air Cleaning will cease functioning. Please carry out appropriate maintenance for the unit. Please carry out unit maintenance every 6 months. If a squeaking or chirping sound is heard, unit maintenance needs to be carried out, even if the AIR CLEAN Indicator Lamp (green) is not flashing. Cleaning the dust collection unit 1. Open the intake grille and remove the air filter on the right. Please consult the instructions for cleaning the air filter on page 12. 4. Wash with water and dry. 1 Soak the plasma filter unit in warm water (104 to 113°F) for 10 to 15 minutes. If the plasma filter unit is extremely dirty, extremely dilute a mild synthetic laundry detergent (low alkalinity or isotope detergent) to 15 times the standard concentration and allow the plasma filter unit to soak in it. 2 Gently move up and down and to the right and left. A soft sponge can also be used to wipe the surface. 3 Rinse with clean water. 4 Shake the plasma filter unit to drain off the water. (If the plasma filter unit is extremely dirty, repeat Steps 1 through 4 two or three more times.) 5 Place the plasma filter unit in the shade and allow it to dry completely. Only use a mild synthetic laundry detergent (low alkalinity or isotope detergent). Never disassemble the plasma filter unit. Never soak the plasma filter unit in hot water. Never wipe the plasma filter unit with a scrub brush or other hard or abrasive items. This will damage the honey comb filter. Never insert a brush into the inside of plasma filter unit for washing. This will damage the internal parts and cause malfunctioning of the plasma filter unit. Never use dryer or other device to blow hot air on the plasma filter unit. This will cause deformation or other damage. Before re-installing the unit, please wait until it is completely dry. If the unit is installed when still w...

Other models in this manual:
Air Conditioner & Split Systems - AOU15RLQ (554.77 kb)
Air Conditioner & Split Systems - AOU15RLQ (554.77 kb)
Air Conditioner & Split Systems - AOU18RLQ (554.77 kb)
Air Conditioner & Split Systems - ASU15RLQ (554.77 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category