Fig. 11 Adjust Solenoid Time IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. IMPORTANT: When mounting thermostat, be sure a new seal washer is placed below the fitting on the capillary line. Push sensing bulb thru tank lid until fitting seats. Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary. 13 SERVICING INSTRUCTIONS (continued) REPLACE HEATING ELEMENT Remove tank cover assembly

downloaded: 4   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

Front 8542 & 8543 8571-3 Panel, Front 8571 8572-10 Panel, Front 8572, 8573 & 8574 114 8718-61 Panel, Bottom Plate (In-line) 8540, 8541, 8542 & 8543 8752-66 Panel, Bottom Plate (3-Station) 8571, 8572, 8573 & 8574 200 8942-6B Brew Chamber, Black All 8942-6 Brew Chamber, Brown All 8707-6 Brew Chamber, Stainless All 8766-11 Brew Chamber, Portion Pack, Black All 8942-6PP Brew Chamber, Portion Pack, Brown All 201 POF Filter Paper (case of 1000) All 19 EXPLODED VIEW & PARTS LIST (continued) HOT WATER T

downloaded: 2   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

Exposed surfaces of the Add a pre-measured amount of brewer, brew chamber and fresh coffee grounds. decanter may be HOT to Gently shake the brew chamber to the touch, and can cause level the bed of grounds. Slide the serious burns. brew chamber into place under the brew head. Fig. 7 Brew Chamber CAUTION: C. POUR-OVER OPERATION Burn Hazard NOTE: Any Integrity™ brewer can be used in the pour-over mode. BE sure “READY TO BREW” light is lit. To avoid splashing or overflowing hot liquids, Place the a

downloaded: 1   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

Front 8542 & 8543 8571-3 Panel, Front 8571 8572-10 Panel, Front 8572, 8573 & 8574 114 8718-61 Panel, Bottom Plate (In-line) 8540, 8541, 8542 & 8543 8752-66 Panel, Bottom Plate (3-Station) 8571, 8572, 8573 & 8574 200 8942-6B Brew Chamber, Black All 8942-6 Brew Chamber, Brown All 8707-6 Brew Chamber, Stainless All 8766-11 Brew Chamber, Portion Pack, Black All 8942-6PP Brew Chamber, Portion Pack, Brown All 201 POF Filter Paper (case of 1000) All 19 EXPLODED VIEW & PARTS LIST (continued) HOT WATER T

downloaded: 8   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

Energize brewer and pour one decanter (64 oz.) of cold water into pour-over opening. When READY TO BREW light comes on, read temperature displayed on thermometer. Adjust thermostat by turning shaft; clockwise increases temperature. 1/8 turn = approximately 10.F. Refer to Table 1 below for proper brewing temperature based on altitude. Upon completion, remove thermometer and reinstall vent tube. THERMOSTAT DIAL-TYPE THERMOMETER IN VENT HOLE TANK LID ASSEMBLY ADJUSTING SHAFT Fig. 10 Checking and Ad

downloaded: 8   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

Install a new seat cup, making sure the knob on the stem is fully inserted into the pocket of the seat cup, and the skirt of the seat cup is fully inserted into the bonnet. 15 SERVICING INSTRUCTIONS (continued) SERVICING INSTRUCTIONS (continued) CAUTION CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced

downloaded: 5   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

They require a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R or 5-20R Receptacle). IMPORTANT: The ground prong of the plug is part of a system designed to protect you from electrical shock in the event of internal damage. Never cut off the ground prong nor twist a blade to fit an existing receptacle. Contact a licensed electrician to install the proper circuit and receptacle. Model 8574 must be wired by an electrician, and requires a 115/230V 20A circuit (50/60 Hz,

downloaded: 2   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

This forces an identical amount of hot water out of the tank and through the spray head into the brew chamber The solenoid uses a flow control device so that flow is consistent between 20 p.s.i. and 90 p.s.i. Length of time the solenoid is open is controlled by the timer. HOT WATER FAUCET The faucet water coil is submerged in the hot water tank and draws heat from the brew water. Water going to the water coil is not controlled by the solenoid valve. The faucet is at supply water pressure any tim

downloaded: 16   File size: 2 mb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

14) Water filter (if used) plugged Replace filter element Bad BREW switch Replace switch Damaged internal component or Examine wiring & connectors, wiring brew switch and solenoid Repair/replace as needed No flow from hot water faucet Faucet valve turned OFF Turn faucet valve ON Faucet plugged Disassemble faucet, clean Poor coffee quality Water not hot enough Adjust water temp 195-205.F Keep brewer, airpots and servers clean. Install a taste and odor filter in water supply, and replace cartridge

downloaded: 1   File size: 752 kb   Manafacture: Bloomfield  
Category: Coffee Makers
@name

tea and coffee carry a 90 day warranty; and, decanters are excluded. THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND/OR INDIRECT OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH BLOOMFIELD PRODUCTS. This warranty is void if it is determined upon inspection by an Authorized Service Agency that the equipment has been modified, misused, misapplied, improperly i