Login:
Votes - 3, Average rating: 4.3 ( )

User manual Stovax, model SLDVT-30NM

Manafacture: Stovax
File size: 4.04 mb
File name: Lennox_Superior_SLDVT_Installation_506009-01.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


5 (127) 8-1/4(209) 14(356) 12 (305) 19(483) *Shelf Height (see table) Do not insulate the space between the appliance and the area above it. 8 (203) 2(51) 4(102) 6(152) 8(203) 10(254) 12(305) 10 (254) 14 (356) 18 (457) 16 (406) 12 (305) Top of Appliance inches (millimeters) Mantel Depth Note -Hood shown as positioned. Figure 9 -Minimum Mantel Clearances Header Model No. Combustible Shelf Height - Inches (millimeters) Top Vent -with One 90 Degree Elbow Secure Vent Secure Flex (flex elbow) SLDVT-30/35 *46-1/2 (1181) *48-1/4 (1226) SLDVT-40/45 *51-1/2 (1308) *53-1/4 (1349) Figure 10 -Minimum Distance to Unprotected Side Wall Top View of Fireplace 45o Protected wall shown in white Inches (millimeters) MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5), with the following exception: When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit. In addition, when the unit is recessed, the side walls surrounding the unit must not extend beyond the front edge of the unit (see Figure 3). *Note: 3 in. (76 mm) above any horizontal/inclined vent component. **Note: See Page 9, Step 1 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. Hearth Extension -Ahearth extension is not requiredwiththis appliance. If a hearth extension is used, do not block the lower control compartment door. Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements. Shelf Height -Toprovide forthelowest possible shelfsurface, the venting attached to the top vent should be routed in a way to minimize obstructions to the space above the appliance. Do not insulate the space between the appliance and the area above it (see Figure 8). The minimum height from the base of the appliance to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Figure 8. Wall Finishes / Surrounds / Mantels Note: Combustible wall finish materials and/or surround materials must not be allowed to en-croach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the appliance face (see Figure 55 on Page 34). Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance face with these exceptions: they must not cover any portion of the removable glass panel. Vertical installation clearances to combustible mantels vary accord- ing to the depth of the mantel. See Figure 9. Mantels constructed of non-combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the fireplace hood. * Includes 3” clearance to combustibles (required above vent components) Combustiblematerialsmay project beyond one side of the fireplace opening as long as they are kept within the shaded areas illustrated here. Combustible Materials Allowed In Shaded Area “Safe Zone” Combustible Walls shown in dark gray At 14" minimum side wall clearance, a combustible wall can project to any length. At 8-1/4" side wall clearance, a combustible wall can project 12" Figure 8 -Shelf Height Minimum Clearances With Top Venting MINIMUM CLEARANCES* Inches (millimeters) Back 1/2 in. (13) or 0 (0) to Spacers Or Dimples Sides 1/2 in. (13) or 0 (0) to Spacers Or Dimples ** Top 3 (76) Floor 0 (0) From Bottom of Unit To Ceiling 64 (1626) Vent 3 (76) Top* / 1 (25.4) Sides & Bottom SERVICE CLEARANCES Feet (meters) Front 3 feet (0.9 meters) Table 5 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS WARNING Failure to position the parts in accordance with these diagrams or failure to use onlypartsspecificallyapprovedwiththisappliance may result in property damage or personal injury. – Efficiencies (%) Model Natural Gas Propane AFUE EnerGuide (P4) AFUE EnerGuide (P4) SLDVT-30 57 51 58 54 SLDVT-35 59 59 61 61 SLDVT-40 62 61 64 61 SLDVT-45 64 59 66 61 10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. FIREPLACE AND FRAMING SPECIFICATIONS Vent Size Coaxial DV Vent Size 4-1/2" Inner 7-1/2" Outer Vertical Venting Through the Ceiling: Frame ceiling opening -Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening, 10-1/2" x 10-1/2" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 18). Notes Diagrams, illustrations and photo- graphs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and price...

Other models in this manual:
Fireplaces - SLDVT-30NM (4.04 mb)
Fireplaces - SLDVT-30NM (4.04 mb)
Fireplaces - SLDVT-30NM (4.04 mb)
Fireplaces - SLDVT-30NM (4.04 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category