Note: Secure Flex vent must be attached to Se- cure Flex terminations only. DO NOT substitute Secure Vent terminations or the Secure Vent adaptor for Secure Flex components. The col- lars of Secure Flex terminations and adaptors have a different diameter than that used with theSecureVentpipe. Additionally,SecureFlex components have an extended length center tube for use in attaching the flexible vent. Figure 35 Flexible Vent Section 5” (127 mm) Radius MinimumFigure 36 Note: Outer Pipe Is Pulled Away To Show The Detail of The Inner Pipe Securing Screw - 3 Places, 120° apart (equally spaced) just Below Gear Clamp SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS Electronic Wiring (See Figure 38 )– Step 4. FIELD WIRING Refer to Section A for millivolt appliances and CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box. See Figure 38. Failure to dosowill resultinapotential safety hazard. The appliance must be electricallygroundedinaccordance withlocalcodesor,intheabsenceof local codes, the National Electrical Code, ANSI/NFPA 70 latest edition. (In Canada, the current CSA C22-1 Canadian Electrical Code). CAUTION: Label all wires prior to disconnec tionwhenservicingcontrols.Wiringerrorscan cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, etiquetez tous les fils avant de lesdebrancher. Des erreursde cablage peuvent entrainer un fonctionnement inadequat et dangereux. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adequatement une fois l'entretien termine. Section B for electronic appliances. The gas valve is set in place and pre-wired at the factory on both models. A. Millivolt Wiring (See Figure 37) – 1. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed behind the bottom panel. Optional wall- mounted switch, thermostat, or one of the optional remote control kits may also be used. 2. If wall-mounted ON/OFF control switch thermostat is selected, mount it in a convenient location on a wall near the fireplace. 3. Wire the control switch within the millivolt controlcircuitusingthe15feetof2conductor wire supplied with the unit. Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. 4. If an optional control switch is installed, turn the appliance-mounted ON/OFF burner control switch to the OFF position. CAUTION: Do Not connect the optional wall switch to a 120V power supply. Note: The electronic appliance must be connected to the main power supply. 1. Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box. 2. Remove the electrical inlet cover plate from the side of the unit by removing the plate's securing screws (see Figure 13 on Page 10). 3. Remove the cover plate's knockout and then feed the power supply wire through the knockout opening and into the unit junction box. 4. Connect the black power supply wire to the lower outlet's red pigtail lead and the white power supply wire to the common terminal of the outlet as shown in Figure 38. 5. Connect the ground supply wire to the pigtail lead attached to outlet's green ground screw. 6. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed behind the bottom panel. Optional wall-mounted switch, thermostat, or one of the optional remote control kits may also be used. The appliance mounted ON/OFF switch needs to be relocated onto the optional style view door, if used. TP-THTPTHAPPLIANCE- MOUNTEDON/OFF SWITCH(OPTIONAL) BK/W(1)BK/W(1) WALL-MOUNTED ON/OFF SWITCH (OPTIONAL) THERMOSTAT (OPTIONAL) JUNCTION BOXBLACKWGR120 VACWALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL) BKRWIRING DIAGRAM MILLIVOLT GAS VALVESTHERMOPILEGAS VALVEFAN(OPTIONAL) Figure 37 Figure 38 JUNCTION BOX W GRBK 120 VAC BKR TRANSFORMER 3V INTERMITTENT ELECTRONIC WIRING DIAGRAM BROWN BROWN BLACK BATTERY BACK-UP BLACK (SENSOR) BLACK (IGNITER) SPARK TO PILOT IGNITER IGNITER MODULE 3V RED BK W GR OPTIONAL BLOWER SWITCH FAN (OPTIONAL) PILOTINOUTVENTLOHITHTPTHTPINORANGE (THTP) BLACK (TP) GREEN (TH) TO WALL SWITCH OR THERMOSTAT See Figure 39 for detailed drawing of junction box / receptacle wiring 25 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way forward and completely to the left or right against the corner posts. The door must be removed first to place the receiver in the lower control compartment. 7. If wall-mounted ON/OFF control or the...

Other models in this manual:
Fireplaces - SLDVT-30NM (4.04 mb)
Fireplaces - SLDVT-30NM (4.04 mb)
Fireplaces - SLDVT-30NM (4.04 mb)
Fireplaces - SLDVT-30NM (4.04 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category