Login:
Votes - , Average rating: ( )

User manual Majestic Appliances, model RFSDV34RFNAU

Manafacture: Majestic Appliances
File size: 367.85 kb
File name: 1e722fc6-9df3-4f76-8e08-eb40b4643473.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information consult with Raypak Australia, your Raypak distributor, qualified installer or accredited Rheem Australia Service Agency. WHAT TO DO IF YOU SMELL GAS? DO NOT try to light any gas appliance. DO NOT touch any electrical switch. Turn off gas supply at the meter. Immediately call Rheem Service, your gas supplier or licensed gasfitter. Note: Some gases are heavier than air and it maybe necessary to check for gas leaks at floor level. CAUTION! DO NOT operate this appliance before reading this instruction booklet. DO NOT place articles or objects on or against the appliance. DO NOT store chemicals or flammable materials in the same room as this appliance. DO NOT store chemicals or flammable materials on, or spray aerosols near this appliance. DO NOT operate with panels, covers or guards removed from the appliance. Part 2: Installation Instructions This gas fireplace must be installed by a qualified installer in accordance with AS5601 and all relevant local building codes. For safe installation and operation please note the following: 1. This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of fireplace high surface temperatures and should stay away to avoid burns or ignition of clothing. 3. CAUTION: Due to high glass surface temperatures children should be carefully supervised when in the same room as the appliance. 4. Under no circumstances should this fireplace be modified or altered. Parts removed for servicing should be replaced prior to operating this fireplace again. 5. Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or service person. A qualified service person should be contacted to inspect the fireplace annually. 6. Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this appliance. 7. The flueing system should be checked once a year and cleaned if required. 8. Keep the area surrounding this appliance clear of combustible materials, gasoline and other flammable vapour and liquids. This heater should not be used as a drying rack for clothing. 9. Under no circumstances should any solid fuels (wood, paper, coal or cardboard etc.) be used in this appliance. 10. The flow of combustion and ventilation air must not be obstructed in any way. 11. When this appliance is installed directly on carpeting, vinyl tile, linoleum or any combustible material other than wood, this fireplace must be installed on a metal or panel extending the full width and depth of the appliance. 12. This appliance requires adequate ventilation and combustion air to operate properly – refer to AS5601 ventilation and combustion air requirements. 13. This appliance must not be connected to a chimney flue serving a separate solid fuel burning fireplace. 14. When the fireplace is not in use it is recommended that the gas control valve be left in the OFF position. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the appliance on. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. It is not unusual for the Raypak Vermont gas fireplace to produce some odour the first time it is burned. This is due to residual oils used during the manufacturing process. Please open all windows to ensure your room is well ventilated. It is recommended that you burn your fireplace for at least 10 hours the first time you use it. Please turn the fan switch in the OFF position during this initial firing. Fig. 1 Locating Your Gas Fireplace A) Flat on wall* B) Room divider* C) Island D) Cross corner E) Flat on wall corner Warning: There is a minimum vertical rise required for the venting, which varies depending on the application. The maximum horizontal run also has restrictions. Before starting the installation read the venting instructions in this booklet and refer to AS5601. The minimum vertical rise for this appliance is 3m. Clearance to Combustibles: Adequate clearances as listed below must be maintained for servicing and proper operation. Back…………………………0 mm Side………………………305 mm Floor………………………...0 mm Top……………………….915 mm Corner………………………0 mm Flue Pipe………………….25 mm DIMENSION RFSDV34 A 667mm B 800mm C 492mm D 762mm E 254mm F 394mm G 114mm H 667mm I 333mm J 495mm K 162mm Gas Specifications Model Gas Type Gas Control Min. MJ/h Input Max. MJ/h Input RFSDV34RFN Natural Radio Freq. 22 32 RFSDV34RFP Propane Radio Freq. 24 32 Gas Inlet and Burner Pressures Natural Gas ULPG Inlet Minimum 1.1 kPa 2.75 kPa Inlet Maximum 3.50 kPa 3.50 kPa Burner Pressure 0.87 ...

Other models in this manual:
Fireplaces - RFSDV34RFNAU (367.85 kb)
Fireplaces - RFSDV34RFPAU (367.85 kb)
Fireplaces - RFSDV34RFPAU (367.85 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category