If error code 3 still shows, replace the thermopiles. If an error code 8 is observed while performing the testing, complete the following: 1. Confirm that the gas valve is not in the REMOTE mode. • If the valve is producing error code 8 while in the REMOTE mode, the valve is defective and should be replaced. • If the valve is producing error code 8 while in the LOCAL mode, go to the next step. 2. Slide the REMOTE/LOCAL switch to REMOTE and program the remote control as per item 6 page 13. The error code will clear itself after approximately 1.5 minutes and return to normal operation. Troubleshooting the Gas Control System Comfort Valve System Control Sequence of Operation with Remote Control Local Path On Path Auto Path Five minute wait period Set manual switch to local or remote Light pilot burner Did the LED stop blinking? Release pilotstat knob Turn pilotstat knob from PILOT to ON Cycle switch once and leave in remote. Press any key on the Remote Control for recognition operation. Review LED failure analysis Move switch from manual to remote. Press any key on the remote control. Move switch back to If manual switch is set to LOCAL, did main burner light and fan turn on? Turn pilotstat knob to PILOT to turn off main burner Yes Turn pilotstat knob to OFF to turn valve completely off. Choose Manual or Remote path. Set switch to manual or remote. Move switch from manual to remote. Press any key on remote control If the manual switch is set to remote, press the mode button to display ON. Does the remote control the main burner and fan? Does remote control change levels of flame height, fan speed? Yes No Set levels of flame height and fan to “0” to shut off main burner and fan Yes Turn pilotstat knob to OFF to turn valve completely off Move switch from local to remote. Press any key on remote control within 30 seconds Text Box: If the manual switch is set to remote, press the mode button to display AUTO. Does the remote control display the room and temperature settings? If the setting is above room temperature on the remote control does the main valve and fan turn on? If the setting is below room temperature on the remote control, does the main valve and fan turn off? Turn pilotstat knob to OFF to turn valve completely off. No No Part 6 Replacement Parts List Insert replacement parts list and parts drawing here. Part 7 Conversion Instructions 1. Disconnect power to the unit and shut off the gas supply. 2. Remove the window frame assembly. (see the Window Frame Assembly section) 3. Carefully remove the logs. (ensure they are not hot) 4. Remove pilot assembly from bracket. 5. Remove the 2 screws holding the burner housing assembly in place. 6. Remove the burner housing assembly. 7. Remove the main and front orifice and replace with the orifice supplied in the conversion kit. Use the small orifice size for the front burner and the bigger orifice size for the main burner. 8. Remove the compression fitting which holds the aluminium tubing in the pilot assembly. This will reveal the pilot injector which must be replaced with the pilot injector provided in the conversion kit. 9. Honeywell Gas Valve -: The Honeywell valve fitted to this appliance is preset for Propane gas. It is convertible to natural gas by a colour coded “conversion screw”. To insert the conversion screw, refer to the instructions and diagrams in the Honeywell Installation Instructions supplied in the conversion kit packaged with the RFSDV34 unit. 10. Reassemble the fireplace in reverse order except for the window frame assembly. Leave the window frame assembly off until the unit has been checked for leaks and the gas supply has been purged. 11. After purging the gas line and checking for leaks with soapy water, replace the window frame assembly. Light the unit and check for frame impingement on logs, adjusting them if necessary. Check the manifold and supply pressures. NOTE: If further assistance is required, refer to the Troubleshooting and Parts List in this manual. Part 8 Wiring Diagram AN240V ACTerminal BlockTransformer240V AC - 110V AC2A (50VA) Fuse - 3 Amp240V AC 50 HzMain Heater SupplySpeed ControlHigh LimitFanRFSDV34 GAS LOG FIRE WIRING DIAGRAM Part 9 Warranty RAYPAK RFSDV34RFN & RFSDV34RFP FREESTANDING GAS LOG FIRE WARANTY - AUSTRALIA ONLY – Rheem Australia * will: a) Repair or, if necessary replace any Raypak RFSDV34 Freestanding Gas Log Fire, or b) Replace any component (or, if necessary, arrange the installation of a Raypak Gas Log Fire, which falls within the Warranty Periods specified below, in accordance with and subject table, conditions and exclusions. Installation Models Period Warranty From date of installation Freestanding Gas Log Fire RFSDV34RFN & RFSDV34RFP Year 1 Labour Freestanding Gas Log Fire RFSDV34RFN & RFSDV34RFP Years 2 Parts Fan and other components Freestanding Gas Log Fire RFSDV34RFN & RFSDV34RFP Years 10 Parts This warranty covers the appliance heat exchanger for 10 years pro-rata with a 1 year labour warranty. Not...
Other models in this manual:Fireplaces - RFSDV34RFNAU (367.85 kb)
Fireplaces - RFSDV34RFNAU (367.85 kb)
Fireplaces - RFSDV34RFPAU (367.85 kb)