Login:
Votes - 2, Average rating: 3.5 ( )

User manual Desa, model (V)CD36TP

Manafacture: Desa
File size: 3.69 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


. If so, contact your local gas supplier. Technical Service You may have further questions about installation, operation or troubleshooting. If so, contact DESA’s Customer Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA’s technical service web site at Specifications (V)CD36RN and (V)CD36TN • Rating: 15,000/21,000 Btu/hr • Gas Type: Natural Gas Only • Ignition: Millivolt • Manifold Pressure: below 2000 ft. elevation - 3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8" (0.94 kPa) • Orifice Size (Main Burner): #44 DMS (0.086") • Minimum Inlet Supply Pressure: 5.5" w.c. (1.1 kPa) • Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ."x 36 ." x 14 ."(908 x 921 x 375 mm) (V)CD36RP and (V)CD36TP • Rating: 13,000/20,000 Btu/hr • Gas Type: Propane/LP Gas Only • Ignition: Millivolt • Manifold Pressure: 10.0" w.c. (2.5 kPa) • Orifice Size (Main Burner): #55 DMS (0.052") • Minimum Inlet Supply Pressure: 11.0" w.c. (2.7 kPa) • Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ."x 36 ." x 14 ."(908 x 921 x 375 mm) (V)CD36RNE and (V)CD36TNE • Rating: 21,000 Btu/hr • Gas Type: Natural Gas Only • Ignition: Electronic • Manifold Pressure: below 2000 ft. elevation - 3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8" (0.94 kPa) • Orifice Size (Main Burner): #44 DMS (0.086") • Minimum Inlet Supply Pressure: 5.5" w.c. (1.1 kPa) • Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ."x 36 ." x 14 ."(908 x 921 x 375 mm) (V)CD36RPE and (V)CD36TPE • Rating: 20,000 Btu/hr • Gas Type: Propane/LP Gas Only • Ignition: Electronic • Manifold Pressure: 10.0" w.c. (2.5 kPa) • Orifice Size (Main Burner): #55 DMS (0.052") • Minimum Inlet Supply Pressure: 11.0" w.c. (2.7 kPa) • Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ."x 36 ." x 14 ."(908 x 921 x 375 mm) Accessories NOTE: All accessories may not be available for allfireplace models. Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA’s Sales Department at 1-866-672-6040, for information. You can also write to the address listed on the back of this manual PROPANE/NATURAL GAS CONVERSION KIT (Not Shown) Note: Not Intended For Use With High- Altitude Models (V)CD36RN-HA or (V)CD36TN-HA PCDM-36RT - Propane/LP Gas Conversion Kit Millivolt Models NCDM-36RT - Natural Gas Conversion Kit Millivolt Models PCDE-36RT - Propane/LP Gas Conversion Kit Electronic Models NCDE-36RT - Natural Gas Conversion Kit Electronic Models LOUVER TRIM KITS (Rolled Louvers Only) LTC36B - Rolled Louver Trim Kit - Brushed Brass LTC36P - Rolled Louver Trim Kit - Platinum REMOTE CONTROL KIT - WRC SERIES (Not Shown) Standard ON/OFF electronic remote control kit. WALL MOUNTED THERMOSTAT CONTROL CONTROL KIT - GWMT1 (Not Shown) Allows easy wall access for thermostatic operation of your fireplace. WALL MOUNTED ON/OFF SWITCH - GWMS2 (Not Shown) Allows burner system to be turned on and off with a wall switch. MANUAL BLOWER KIT - BK Manual variable control blower accessory provides better heat distribution. Complete installation and operating instructions in- cluded in this manual. THERMOSTATICALLY - CONTROLLED BLOWER KIT - BKT Provides better heat distribution Blower turns off and on automatically, as needed. Complete installation and operating instructions included in this manual. RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - HRC200 SERIES Allows fireplace to be operated manually or thermostatically-controlled mode. You can adjust your heat settings and turn the fireplace on or off without leaving the comfort of your easy chair. A wall mount docking station is included. RECEIVER AND HAND-HELD ON/OFF REMOTE CONTROL KIT HRC100 SERIES Allows the fireplace to be turned on and off conveniently. A wall mount docking station is included. Illustrated Parts Breakdown FIREPLACE ASSEMBLY FOR MODELS (V)CD36RN, (V)CD36RP, (V)CD36TN, (V)CD36TP (V)CD36RN-HA, (V)CD36TN-HA 1-281091-11231656713191-41-3241415171811 PARTS LIST FIREPLACE ASSEMBLY FOR MODELS (V)CD36RN, (V)CD36RP, (V)CD36TN, (V)CD36TP (V)CD36RN-HA, (V)CD36TN-HA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 44 of this manual. ( V)CD36TN-HA ( V)CD36RN-HA ( V)CD36RN ( V)CD36RP ( V)CD36TN ( V)CD36TP KEY NO. PART NO. DESCRIPTION QTY. 1 116108-01 Log Set • • • • • • 1 1-1 116109-01 Burner Base Log • • • • • • 1 1-2 116110-01 Rear Log • • • • • • 1 1-3 111802-05 Right Top Log • • • • • • 1 1-4 111802-04 Left Top Log • • • • • • 1 2 115615-01 Burner Assembly Complete (See pages 41 an 43) • • • • • • 1 3 114889-01 Junction Box Duplex Plug • • • • • • 1 4 114880-01 Heat Deflector • • • • • • 1 5 114875-01 Fireplace Surround • • • 1 114875-02 Fireplace Surround • • • 1 6 114876-01 Fireplace ...

Other models in this manual:
Fireplaces - (V)CD36RNE (3.69 mb)
Fireplaces - (V)CD36RP (3.69 mb)
Fireplaces - (V)CD36RPE (3.69 mb)
Fireplaces - (V)CD36TN (3.69 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category