Install the nailing flanges - 8 (CDST), 4 (CDPF, CDCL and CDCR) - as shown in Figure 7 using the existing screws. Position the fireplace within the framing. When required, the flanges may be bent 90 degrees by hand or with the assistance of a hammer. Use wood screws to secure the nailing flanges to the framing. See Table 2 on page 4 for clearances of framing members to cabinet parts in the nailing flange area. The nailing flange itself is exempt from these clearances. Floor Nailing Tabs Secure the fireplace to the floor as shown in Figure 7. Turn tabs down and secure to the floor with 8d nails or other appropriate fasteners on all sides of the unit which do not have viewing glass panels. CDST SHOWN (CDPF - NO NAILING FLANGES ON END WITH GLASS PANEL) CDCL SHOWN (FOR CDCR VIEW, INTERCHANGE SIDES) Remove these two screws and use them when installing the nailing flanges. Nailing Flanges Figure 7 DETAILED INSTALLATION STEPS 3 - Lift the pressure relief plates and remove the cardboard from underneath each of them. 4 - Open the control compartment access panel by actuating the spring loaded magnetic catches securing the panel, gently depressing the outer top corners of the panel until the catches "pop" the panel free, allowing it to swing out and down to open. 5 - Open the two latches (located under the firebox floor) securing the glass enclosure panel. Remove the panel by tilting it outward at the bottom and lifting it up. Set the door aside protecting it from inadvertent damage. See Figure 57 on page 24. The appliance is shipped with all gas controls and components installed and pre-wired. 1 - Remove the shipping carton. 2 - Remove the top louver panel (see Figure 6). Note: The CDST fireplace is installed in the framing by cocking it at an angle, fitting the collar side in first and then twisting and pushing the other side in. To minimize the obstruction, it is helpful to make sure the cap is removed from the rear collar. If the appliance is to be elevated above floor level, a solid continuous platform must be constructed. Headers may be in direct contact with the appliance top spacers but must not be supported by them or notched to fit around them. All construction above the appliance must be self supporting, DO NOT use the appliance for structural support. All framing details must allow for a minimum clearance to combustible framing members as shown inTable 2 on page 4. Step 1. FRAMING Frame these appliances as illustrated in Figures 9 (CDST), 10 (CDPF), 11 (CDCL) or 12 (CDCR). EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V V V V V F C Fixed Closed Window Operable Window B B A B H M I D 3 ft. 3 ft. A A A = 9” in U.S. = 12” in Canada L B J X E V A G Inside Corner Detail *18” Ventilated Soffit Horizontal Termination Detail D Exterior Wall Center Line of Termination C 18” Inside Corner BC C * See Item D in the Text Below. EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V V V V V F C Fixed Closed Window Operable Window B B A B H M I D 3 ft. 3 ft. A A A = 9” in U.S. = 12” in Canada L B J X E V A G Inside Corner Detail *18” Ventilated Soffit Horizontal Termination Detail D Exterior Wall Center Line of Termination C 18” Inside Corner BC C * See Item D in the Text Below. X = Air Supply Inlet V = Vent Terminal = Area where Terminal is not Permitted Canadian Installation* US Installation** A = Clearance above grade, veranda, porch, deck, or balcony. 12 inches (30cm)* 12 inches (30cm)** B = Clearance to window or door that may be opened. 6 in (15cm) for appliances < 10,000 Btuh (3kW), 12 in (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36 inches (91cm) for appliances > 100,000 Btuh (30kW)* 6 in (15cm) for appliances < 10,000 Btuh (3kW), 9 in (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12 inches (30cm) for appliances > 50,000 Btuh (15kW)** C = Clearance to permanently closed window 12" (305mm) minimum to prevent window condensation 9" (229mm) minimum to prevent window condensation D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 18 inches (458mm) from the center line of the terminal 18" (458mm) 18" (458mm) E = Clearance to unventilated soffit 12" (305mm) 12" (305mm) F = Clearance to outside corner 5" (12.7cm) minimum 5" (12.7cm) minimum G = Clearance to inside corner 6" (15.2cm) minimum 6" (15.2cm) minimum H = Clearance to each inside of center line extended above meter/regulator assembly 3 feet (91cm) within a height of 15 feet above the meter/regulator assembly* 3 feet (91cm) within a height of 15 feet above the meter/regulator assembly** I = Clearance to service regulator vent outlet 3 feet (91cm)* 3 feet (91cm)** J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in (15cm) for appliances < 10,000 Btuh (3kW), 12 in (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36 inches (91cm) for appliances > 100,000 Btuh (30...
Other models in this manual:Fireplaces - CDCR-CEN (4.28 mb)
Fireplaces - CDCL-CEP (4.28 mb)
Fireplaces - CDCL-CEN (4.28 mb)
Fireplaces - CDCL-CMN (4.28 mb)