User manual Monessen Hearth, model SSDVST-CNM-B

Manafacture: Monessen Hearth
File size: 4.94 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


OFF/ON Switch Connect wires to terminals 4. Press the OFF/ON switch into bracket as shown below (it will snap into place). Figure 44 B. Electronic Wiring (See Figures 45 and 46) Notes: • The electronic appliance must be connected to the main 120 VAC power supply. • The junction box can be installed in any of the 4 outside corners of the control compartment (it can be found factory installed in the right front corner viewed from the valve access side (where it should be reinstalled if an optional blower kit is installed). 1. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the location on appliance where junction box is to be installed. 2. Open the control compartment access panel (see Control Compartment Access Instructions on Page 27). 3. Remove the junction box/outlet receptacle assemblybyremovingthesecuringscrewat the front right corner of the unit. See Figure 45. 4. Remove the outlet receptacle from the junction box by removing the two securing screws. Figure 43 -Millivolt Wiring Diagram Field Wired FactoryWired THTP TH TP * Optional Control Switch Thermopile Schematic Representation Only • If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105 C - 18 gage wire. * Optional Kits Installed - ON/OFF wall switch, unit mounted burner ON/OFF switch, wall thermostat or remote control.receiver. PT* * Twist wires together to operate unit solely by manipulating the gas valve control knob; or connect wires to optional control switch (wall switch, remote control or wall thermostat to operate unit. 5. 5. 6. Connect the power supply wires to the receptacle as shown in Figure 46 on Page 26. 7. Connectthegroundsupplywiretothegreen wire attached to the outlet receptacle’s green ground screw. 8. Wire and install the outlet receptacle to junction box. Next, install into the chosen cornerofthecontrolcompartmentasshown in Figure 45. 9. After the receptacle/junction box wiring is complete, install the field-provided metal junction box cover plate (see Figure 45). Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose on top of the appliance. IMPORTANT NOTE The gas valve OFF/ON switch is shown in Figure 46 on Page 26. It is integral with the gas valve and should be set to the ON position. Figure 45 Outlet Receptacle Junction Box Field-provided Metal Junction Box Cover Plate With Screw View Of Right Bottom Corner Of Unit Receptacle, Junction Box and Cover Plate Installation Fireplace Side Junction Box knock-out (2 places each side) Valve Access Side Press snap bushing into the knock-out for control switch wires. CAUTIONS • Remove the carton support from the control compartment before operating the appliance. • Ensure that wires are positioned awayfrom hotsurfacesandsharp edges. • Do not connect the optional wall switch to a 120 Volt AC power supply. Step 5. WIRING -OPTIONAL FORCED AIR BLOWER KIT FBK-100, FBK-200 and FBK-250 Kits (See Figure 46 for wiring) - An electrical receptacle is provided for the installation of the FBK-100, FBK-200 and FBK250 forced air blower kits. Electrical power must be connected to this receptacle in order to operate these blowers. Install the blower kits according to the installation instructions provided with the kits. Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits Schematic Representation Only Relay Module C/W FBK-250 only. Plug blower into J-Box receptacle for FBK-100 or FBK-200 application. See View A for J-Box wiring. Optional Blower *OFF/ON Switch (Integral with Gas Valve) Honeywell Electronic Gas Valve 120 VAC Primary Secondary Optional Control Switch Junction Box Pilot Burner Assembly BL BL Field Wired Factory Wired BK = BLACK BL = BLUE R = RED W = WHITE G = GREEN BK W BK BK BL R GROUND 24 V Transformer View A J-Box Wiring when using unit mounted relay module. BK W G CAV021Igniter Connector * Leave the OFF/ON switch, which is integral with the gas valve, in the ON position. ** Optional Control Switches: Wall Switch, Wall Thermostat or Remote Control Receiver. Notes: 1. If any of the original wire as supplied must be replaced, use Type AWM 105°C -18 gage wire ONLY. 2. 120 VAC, 60 Hz -Less than 3 Amps. Caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Junction Box Tab Intact Tab Broken Plug blower into this receptacle neerG-dnuorG* Wall-mounted ON/ OFF Blower Switch or Variable Speed Control Switch. Blower Ground etihW-lartueN120 VAC -Black Green Ground Screw White Green Neutral Side of Receptacle Hot Side of Receptacle Red Black J-BOX WIRING FOR WALL SWITCH BLOWER CONTROL Figure 46 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 6. CONNECTING GAS LINE Step 6. CONNECTING GAS LINE The flex-line method is acceptable in the U.S.A. where local codes permit, however, Canadian requirements vary depending on ...

Other models in this manual:
Fireplaces - SSDVPF-CNE-B (4.94 mb)
Fireplaces - SSDVPF-CNE-B (4.94 mb)
Fireplaces - SSDVPF-CNE-B (4.94 mb)
Fireplaces - SSDVPF-CNE-B (4.94 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category