Login:
Votes - 4, Average rating: 4.3 ( )

User manual Country Flame, model FP42

Manafacture: Country Flame
File size: 2.46 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


FIGURE 13: ELECTRICAL JUNCTION BOX FIGURE 13 shows the location of the electrical junction box cover. A certified electrician should remove the cover of this junction box to connect the Smart Fireplace Furnace’s blower system to the household electrical grid and the supplied thermostat with proper temperature rated romex wire. WARNING: Failure to properly wire in the blower system can lead to shock hazard, a malfunctioning blower system, or could create a fire hazard. Contact a certified electrician to ensure proper installation of the Smart Fireplace Furnace blower system. NOTE: All wiring should be completed before masonry work is complete. Included with this blower system as: a) Two multi-speed blowers rated at 120 volts, 60Hz, 6.5 amperes, and 525 CFM each. b) Two ducts for mounting blowers to fireplace. c) Two blower grille covers with rheostat fan speed controls pre-mounted. d) 10 wire nuts. e) One Wall mountable thermostat. f) One air discharge snap disc mounted & wired in front air discharge duct (right side.) g) Electrical box, right side to connect snap disk to thermostat connection. FIGURE 14 shows the proper components and wiring procedure for connecting the blower system. Follow all local electrical and safety codes as well as the National Electrical Code when installing electrical wiring. FIGURE 14: ELECTRICAL SYSTEM A certified electrician should provide the electrical circuit and connect the fireplace furnace to the electrical supply. The blower systems and the Smart Fireplace Furnace must be electrically grounded. Grounding can be accomplished with a grounded metal-clad raceway system or by using a separate ground wire connected to the bare metal of the blower frame and fireplace box or other suitable means. Disconnect all power sources from the fireplace before working on or near the blower motor system or its components. Be careful when touching the exterior of an operating blower motor. Modern motors are built to operate at high temperatures that may be hot enough to cause pain or personal injury. Be careful around the moving parts of the blower motor system. When installing the blower system ensure that the power cables and blower leads remain clear of sharp objects. Further, ensure that the power cables or motor leads are not kinked. Never allow the power cables or motor leads to come in contact with oil, grease, hot surfaces, or chemicals. Utilize the two high temperature wires (red and white) provided by Country Flame to connect the air discharge snap disc to the electrical system as shown in FIGURE 14. Use the high temperature wire (green/yellow) to ground the fireplace to the right blower box. The green/yellow wire installed by Country Flame at the factory should be connected to one of the screws used to hold the air discharge snap disc to the fireplace. Connect the other end of the green/yellow wire to the right blower box or another earth ground coming from the circuit breaker box. The installing electrician should ensure proper grounding is accomplished for both blower boxes and the fireplace unit as per FIGURE 14. Screws and wire nuts are provided by Country Flame to ensure all parts are available during installation. High temperature blower motor systems are lubricated at the factory and should require no further lubrication; however, at higher inlet temperatures, increased bearing life can be achieved by annually re-lubricating the motors with 10 to 20 drops of Anderol Number 465 high temperature synthetic lubricant. DO NOT USE petroleum-based oil, as bearing failure will result. Chapter 2 DUCTING OPTIONS .. Properly ducting the Smart Fireplace Furnace will provide years of comfort because properly ducted fireplaces will allow for a more uniform distribution of heat throughout the home. Many ducting options are possible with the Smart Fireplace Furnace. Which option is selected depends on your installer’s knowledge, local codes, and the desired results expected from the completed system. During the installation process, it is important to determine and ensure the compatibility of the Smart Fireplace Furnace with any gas or oil fired furnace that is to be installed in the residence. As a minimum, a test must be conducted to ensure the furnace installation is compatible with the existing Smart Fireplace Furnace’s operating range of air temperature rise and/or external static pressure of those marked on the nameplate of the central furnace. FIGURE 15: (OPTIONAL) SIDE VENTED FIREPLACE CAUTION: The warm-air supply outlet of the Smart Fireplace Furnace should not be connected to the cold-air return inlet of the central furnace system. These warm-air to cold-air connections must not be made because the possibility exists of components in the central furnace system overheating and causing the central furnace system to operate other than as it was intended to operate. OPTIONAL DUCT RINGS are available from Country Flame Technologies and are unique to fireplace models. FIGURE 15 shows ...

Other models in this manual:
Fireplaces - Fireplace FP33 (2.46 mb)
Fireplaces - FP37 (2.46 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category