Manafacture: Lennox Hearth
File size: 898.38 kb
File name:
|
manual abstract
Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated firmly. 2. Position the glass enclosure panel in front of the firebox opening at a 45 degree angle and engage the top flange over the lip at the top of the firebox opening. 3. Swing the glass enclosure panel down and back. Ensure the gasket seats evenly as the panel draws shut. Engage the Vee-flanges at the bottom of the panel with the latches and then close the latches to secure the panel. 4. Close the bottom control compartment access panel. 5. Reinstall the top and bottom bustle, and the top louver assembly or radiant panel. Burner Adjustments Note -Theair shutter for the burner primary air opening is factory-set. Do not adjust the factory- set position. The factory-set position is shown inFigure 7. *Note -Do Not Adjust the Factory-Set Position. The shutter opening is shown in the table below. Orifice *Air Shutter OpeningBurner Venturi Tube Millivolt Shown MAIN BURNER FACTORY SHUTTER SETTING Models Natural Gas inches (mm) Propane Gas inches (mm) EBVST EBVPF EBVCR EBVCL 1/16 (1.5) 7/16 (11) Figure 7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Log Placement The log set is located within the firebox area. One plastic bag of glowing embers, one plastic bag of decorative volcanic stone and one bag of vermiculate, is located in the bottom compartment. Refer to the Log Placement Guide supplement for detailed placement instructions. See Figure 9 for vermiculate and glowing embers placement. Place a few dime-sized pieces of rockwool on the pan burner in front of the burned out area on both sides of the log set. The pieces of rookwool may touch one another, but should not overlap each other. Millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top ..." (10 mm) at the pilot generator (thermopile) and the top ..." min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports. See Figure 11. To light the burner, refer to the lighting instructions on pages 14 and 15. Figure 9 Figure 10 Figure 8 Install the vermiculite, decorative volcanic stone and glowing embers (rockwool)- Spread vermiculite on the simulated brick floor of the firebox around the burners to simulate ashes. Maintain a ... in. gap between the bottom of the horizontal grate section and the top of the pile of vermiculite. Sprinkle the decorative volcanic stone on the vermiculite as shown in Figure 9. BURNER POSITIONING PAN BURNER PILOT ASSEMBLY BACK OF FIREPLACE PAN BURNER FIREBOX BOTTOM Glowing Embers (Rockwool) Vermiculate And Volcanic Stone On Firebox Bottom WARNING: LOG SET GETS VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOG SET IS COOL. TURN OFF ALL GAS TO THE APPLIANCE BEFORE INSTALLING THE GRATE AND LOG SET. WARNING: THIS APPLIANCE IS NOT DESIGNED TO BURN WOOD. ANY ATTEMPT TO DO SO COULD CAUSE IRREPARABLE DAMAGE TO YOUR APPLIANCE AND PROVE HAZARDOUS TO YOUR SAFETY. WARNING: THE SIZE AND POSITION OF THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELIABLE AND ATTRACTIVE FLAME PATTERN. ANY ATTEMPT TO USE A DIFFERENT LOG SET IN THE FIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUSTION, SOOTING, AND POOR FLAME QUALITY. MILLIVOLT Thermocouple Hood Ignitor Rod ..." Min (9 mm) Thermopile Pilot Nozzels MILLIVOLT Thermocouple Hood Ignitor Rod ..." Min (9 mm) Thermopile Pilot Nozzels Figure 11 Electronic Appliance Checkout To light the burner, refer to the lighting instructions onpage 16 and 17. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 12. ELECTRONIC Proper FlameAdjustment Pilot Nozzle 3/8 To 1/2 Inch(9 mm to 13 mm) Ground Electrode Flame Rod Hot Surface Igniter Figure 12 With proper care and maintenance, your appliance will provide many years of enjoyment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor. WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION. Thermopile THTP TH TP White WhiteBlack Millivolt Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. *OPTIONAL WALL-MOUNTED ON/OFF SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE RECEIVER *Turn the appliance-mounted ON/OFF burner control switch to the OFF position if an optional control switch is installed. Factory Wi...
Other models in this manual:Fireplaces - EBVCLNM (898.38 kb)
Fireplaces - EBVCLPM (898.38 kb)
Fireplaces - EBVCRNE (898.38 kb)
Fireplaces - EBVCRNM (898.38 kb)