|
manual abstract
HILOOFFONPILOTTPTHTHTP To wall switch, remote control or thermostat To thermopile Thermostat Wire Table 14 GA. 16 GA. 18 GA. 20 GA. 22 GA. 50 Ft. 32 Ft. 20 Ft. 12 Ft. 9 Ft. Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. LengthWire Size Max. Length Regency E21 Gas Fireplace Insert OPERATING INSTRUCTIONS FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes. 2) Ifrequired,adjustingtheprimaryairtoensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize. 3) Check for proper draft. CAUTION Any alteration to the product that causes sooting or carboning that results in damagetotheunitisnottheresponsibility of the manufacturer and will not be covered by the warranty. OPERATING INSTRUCTIONS Beforeoperatingthisappliance,proceedthrough the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass door is in place. Never operatetheappliancewiththedoorglass removed. 5) Verify that all venting and the cap is unobstructed. 6) Verify log placement. If the pilot cannot be seen when lighting the unit - the logs or the embers have been incorrectly positioned. 7) The unit should never be turned off and on again without a minimum of a 60 second wait. 8) When lighting the appliance, the inside of the glass may fog up, this will burn off after a few minutes of operation. GasInShutOffHi-LowPilotAdjustGasOutTPTHTPTH LIGHTING PROCEDURE IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed. 1) Open the bottom louver assembly 2) If the control knob is in the "OFF" position proceed to Step 5. 3) Push in gas control knob slightly and turn clockwise to "OFF". Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 4) Wait five minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you do smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step. 5) Turn the gas control counter clockwise to "PILOT". 6) Push in control knob all the way and hold in. Continually push and release the black button on spark igniter until pilot lights. Continue to hold the control knob in for approximately one minute, then release the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob. 7) Turn gas control knob counter clockwise to "ON". 8) Use the rocker switch to operate main burner. 9) Rotate the variable flame control to adjust the flame height higher or lower. 10) Close the bottom louver assembly. SHUTDOWN PROCEDURE 1) Use the rocker switch to turn off the main burner. 2) Open the bottom louver assembly. 3) Push in the gas control knob slightly and turn clockwise to "OFF". Do not force. 4) Disconnect all electric power and gas to the appliance if service is to be performed. FIRST FIRE The first fire in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass panel may require cleaning after the unit has cooled down. DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Do not use abrasive cleaners on the glass. Note: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up. DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE. Regency E21 Gas Fireplace Insert OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS A)Thisappliancehasapilotwhichmustbelightedbyhand.Whenlightingthepilot,followtheseinstructionsexactly. B)BEFORELIGHTINGsmellallaroundtheapplianceareaforgas.Besuretosmellnexttothefloorbecausesomegasisheavierthanairandwillsettleonthefloor. WHATTODOIFYOUSMELLGAS-Donottrytolightanyappliance-Donottouchanyelectricswitch,donotuseanyphoneinyourbuilding. -Immediatelycallyourgassupplierfromaneighboursphone.Followthegassupplier’sinstructions. -Ifyoucannotreachyourgassupplier,callthefiredepartment. C)Useonlyyourhandtopushinorturnthegascontrolknob.Neverusetools.Iftheknobwillnotpushinorturnbyhand,don’ttrytorepairit,callaqualifiedServiceTechnician.Forceorattemptedrepairmayresultinafir...
Other models in this manual:Fireplaces - E21-NG1 (10.31 mb)