Manafacture: Cres Cor
File size: 378.9 kb
File name:
|
manual abstract
10 (6/08) Page 1 of 13 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS CO151FUA12B-Q1 CO151HUA6B-Q1 CO151FPUA12B-Q1 CO151F1818B-Q1 RO151FUA18B-Q1 RO151F1332B-Q1 CO151H189B-Q1 CO151XUA5B-Q1 CO151X185B-Q1 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • Ovens with Microprocessor Controls FL-2269 Rev. 10 (6/08) Page 2 of 13 5925 Heisley Road • Mentor, OH 44060-1833 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3, 4 OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 5, 6 Illustration, Figure 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 MAINTENANCE INSTRUCTIONS How to Clean the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Trouble Shooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 7 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8, 9 Illustrations; Hot Unit (Figures 3 and 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10, 11 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 OPTIONAL PRODUCT KEYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 SERVICE POLICY and AGENCY LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FL-1400 WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • 5925 Heisley Road • Mentor, OH 44060-1833 Ovens with FL-2269 Microprocessor Controls Rev. 10 (6/08) Page 3 of 13 INSTALLATION INSTRUCTIONS VENTING YOUR OVEN: 1. The purpose of ventilating hoods is to direct and capture 3. Most jurisdictions consider our low-temperature ovens smoke, grease-laden vapors, heat, odors, or fumes. (maximum temperature is 350°F/177°C) as low-heat appliances not requiring vent hoods. 2. Low temperature equipment (maximum temperature250°F/121°C) does not produce heat, odors, fumes, grease-4. Installation must conform with local codes. The authority laden vapors or smoke and is not required to be vented. having jurisdiction of enforcement of the codes will have the responsibility for making interpretations of the rules. UNIT SPECIFICATIONS: All units use three (3) elements (2670 watts each). All units are rated 8200 watts. Water units have one (1) immersion element (1850 watts). MODEL NOS. CONVECTION OVENS CO151FUA12B2081Q1 CO151FUA12B2401Q1 CO151FUA12B2083Q1 CO151FUA12B2403Q1 CO151FPUA12B2081Q1 CO151FPUA12B2401Q1 CO151FPUA122083Q1 CO151FPUA122403Q1 CO151F1818B2081Q1 CO151F1818B2401Q1 CO151F1818B2083Q1 CO151F1818B2403Q1 (AC SERVICE) ELECTRICAL SPECS ELEC. LOAD POWER SUPPLY REQUIREMENT ALL 3 PHASE IS 3 WIRE + GROUND Ph Hz. Amps Volts Amps Ph Volts NEMA 1 1 60 60 39 34 208 240 50 50 1 1 208 240 6-50P 6-50P 3 3 60 60 23 20 208 240 30 30 3 3 208 240 L15-30P L15-30P 1 1 60 60 39 34 208 240 50 50 1 1 208 240 6-50P 6-50P 3 3 60 60 23 20 208 240 30 30 3 3 208 240 L15-30P L15-30P 1 1 60 60 39 34 208 240 50 50 1 1 208 240 6-50P 6-50P 3 3 60 60 23 20 208 240 30 30 3 3 208 240 L15-30P L15-30P Volts 208 240 208 240 2...
Other models in this manual:Electric Ovens - CO151FPUA12B-Q1 (378.9 kb)
Electric Ovens - CO151F1818B-Q1 (378.9 kb)
Electric Ovens - CO151HUA6B-Q1 (378.9 kb)
Electric Ovens - RO151F1332B-Q1 (378.9 kb)