Set steamer on counter and bolt down securely with 3/8 - 16 bolts (not supplied). STACKING KIT Follow instructions in the stacking kit when installing stacked convection steamers. 24" 20" 2" 27 1/2" 23 1/2" Drill 1/2" holes through counter top Mark 4 corners on counter top PL-50819 Fig. 1 ELECTRICAL CONNECTION WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT. The wiring diagram is located on the right side panel as you face the steamer. ELECTRICAL DATA Total KW Volts / Hz / Ph Kilowatts Per Phase Rated Amps Circuit Size (Amps) Fuse Size or Circuit Breaker Size * (Amps) 90°C Copper Wire Size 3 Phase Amps Per Line Wire 1 Phase AmpsL1 - L2 L2 - L3 L1 - L3 L1 L2 L3 7.5 208 / 60 / 1 36 50 50 8 7.5 240 / 60 / 1 31 45 45 8 7.5 208 / 60 / 3 2.5 2.5 2.5 21 21 21 30 30 10 7.5 240 / 60 / 3 2.5 2.5 2.5 18 18 18 25 25 14 7.5 480 / 60 / 3 2.5 2.5 2.5 9 9 9 15 15 16 10 208 / 60 / 1 48 70 70 8 10 240 / 60 / 1 42 60 60 8 10 208 / 60 / 3 3.3 3.3 3.3 28 28 28 40 40 10 10 240 / 60 / 3 3.3 3.3 3.3 24 24 24 35 35 10 10 480 / 60 / 3 3.3 3.3 3.3 12 12 12 15 15 16 15 208 / 60 / 1 72 100 100 6 15 240 / 60 / 1 63 90 90 6 15 208 / 60 / 3 5 5 5 42 42 42 60 60 8 15 240 / 60 / 3 5 5 5 36 36 36 50 50 8 15 480 / 60 / 3 5 5 5 18 18 18 25 25 14 * Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition. PLUMBING CONNECTIONS WARNING: PLUMBING CONNECTIONS MUST COMPLY DRAIN VENT WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. Connect the water supply line to the 3/8" NPT (internal thread) copper tube inlet. The 3/8" water line supplies water to both the generator tank and the cooling system where steam is condensed before entering the drain line. Install the line strainer provided. A manual shutoff valve must be provided convenient to the steamer. DRAIN CONNECTIONS 1 1/4 NPT TO OPEN GAP DRAIN PL-50880 BY CUSTOMER The drain connection (Fig. 2) must be 1" IPS down, preferably with one elbow only, maximum length of 6 feet, and piped to an open gap type drain. CAUTION: In order Fig. 2 to avoid any back pressure in the steamer, do not connect solidly to any drain connection. WATER QUALITY The water supply connected to this steamer should contain no more than 2.0 grains of hardness per gallon with pH from 6.5 to 8.0. This degree of hardness and pH can easily be obtained with the use of a properly maintained water softener. Water supplies vary from one location to another. A local water treatment specialist should be consulted before installing any steam generating equipment. Untreated water contains scale producing minerals which can precipitate onto the surfaces in the boiler. Due to the temperatures in...
Other models in this manual:Electric Ovens - COUNTER CONVECTION STEAMERS 52396 (88.29 kb)
Electric Ovens - COUNTER CONVECTION STEAMERS 52398 (88.29 kb)
Electric Ovens - COUNTER CONVECTION STEAMERS 52399 (88.29 kb)
Electric Ovens - COUNTER CONVECTION STEAMERS VSX3 (88.29 kb)