manual abstract


2. Disconnect the terminal wires from the switch. 3. Obtain a continuity tester or a volt-ohm meter. If neither of these instruments is available, make a continuity tester using a battery and a bulb. See Figure B-1. 4. Connect the wires of the continuity tester to the switch terminals, as shown in Figure B1, and test the switch in the ON and OFF positions. The switch should show continuity only when in the ON position. + battery _ switch terminals toggle switch Figure B-1. Toggle Switch Continuity Test. Belshaw Bros., Inc. .. 1750 22nd Ave. S. .. Seattle, WA 98144 .. Phone 206-322-5474 .. Fax 206-322 MN-1126EN 618L, 624, and 634 Electric Fryers Testing the Continuity of the Thermostat WARNING To avoid the possibility of electric shock, disconnect the machine from the power source before testing. 1. Disconnect the machine from the power supply. 2. Disconnect the terminal wires from the thermostat. 3. Connect the continuity tester across the B terminals indicated in Figure B-2. This set of contacts should be closed whenever the thermostat is on. To test, start with the thermostat in the OFF position. Then turn the thermostat up until you hear a distinct click (at about the 175. F/79. C setting). At this time, there should be continuity across the B terminals. 4. Connect the continuity tester across the A terminals indicated in Figure B-2. Start with the thermostat in the OFF position and turn the thermostat up until you hear a distinct click. If there is no continuity (the indicator or light does not come on), proceed to step 5. 5. With the continuity tester still connected, turn the thermostat knob to OFF and remove the knob. There is an adjusting screw in the center of the knob stem. Turn it counterclockwise until there is continuity. If there is no continuity (the indicator or light does not come on), then the thermostat is defective. If there is continuity, proceed to step 6. 6. Immerse the thermostat sensing bulb in a pan of boiling water and set the thermostat at about 212. F/100. C. The continuity tester’s indicator or light should go off. If the indicator or light does not go off, increase the temperature setting of the thermostat until it does. Then recalibrate the thermostat according to the manufacturer’s instructions. If the indicator or light will not go off at any setting or recalibration, then the thermostat is defective. “B” terminals “A” terminals Figure B-2. Thermostat Terminals. Belshaw Bros., Inc. .. 1750 22nd Ave. S. .. Seattle, WA 98144 .. Phone 206-322-5474 .. Fax 206-322 618L, 624, and 634 Electric Fryers MN-1126EN C Parts Lists The following pages contain lists of the parts that make up the 618L, 624, 634 Fryers. You can use the parts lists to order replacement parts. When you do, please provide electrical information about your fryer. Some of the part numbers vary according to the voltage, phase, and cycle of the machine. IMPORTANT The parts lists and assembly drawings are meant as guides. Because Belshaw constantly improves its products, parts lists and assembly drawings may not reflect the most recent design changes. Belshaw Bros., Inc. .. 1750 22nd Ave. S. .. Seattle, WA 98144 .. Phone 206-322-5474 .. Fax 206-322 MN-1126EN 618L, 624, and 634 Electric Fryers Belshaw Bros., Inc. .. 1750 22nd Ave. S. .. Seattle, WA 98144 .. Phone 206-322-5474 .. Fax 206-322 618L, 624, and 634 Electric Fryers MN-1126EN FIGURE C-1. 618L FINAL ASSEMBLY. BILL OF MATERIAL BILL OF MATERIAL ITEM QTY. PART NO. DESCRIPTION ITEM QTY. PART NO. DESCRIPTION 1 1 or 618-1042 or Pre-Wire Panel Assembly–U.L. 28 1 624-40 Drain Nipple 1 or 618-1043 or Pre-Wire Panel Assembly–CSA and 29 1 618L-98 Drain Valve Extension Knob 208/236 Volt Export 1 or 618-1044 or Pre-Wire Panel Assy.–440/480 Volt, 30 1 618L-516 Extension Rod Assembly Transformer (Shown) (See Fig. B-2) 1 618-1048 Pre-Wire Panel Assembly–380 Volt 31 1 FT100-50 Set Collar Export 2 1 618-161 Electrical Box Cover 32 1 --------1” Plastic Insulating Bushing 3 1 or 618L-1044 Cabinet Assembly–Painted 33 1 618-128 Label–Ground or 1 618-1044SS Cabinet Assembly–Stainless Steel 34 1 618-131 Ground Lug 4 1 618-540 Electrical Box Assembly 35 1 --------1” EMT Locknut 5 1 618L-103 Label–”Drain Valve” 36 1 MDD-459 Label–”Warning” 6 1 EP18/24Label–” Belshaw” 37 1 618L-105 Label–”Warning,” Cutter Mounting 140 7 3 618-116 Label–”Caution–Hot” 38 4 624-143 Adjustable Leg 8 2 634-619 Bracket Plate Assembly 9 1 618-17 Door Knob FASTENERS 10 2 634-63 Cutter Column Mounting Bar Spacer ITEM QTY. DESCRIPTION 11 1 634-59 Heater Head Mounting Bracket–L.H. A 1 8 x 3/8 Slotted Round-Head Sheet Metal Screw 12 1 634-75 Bracket Sleeve B 8 1/4-20 x 5/8 Hex-Head Machine Screw 13 1 634-60 Heater Head Mounting Bracket–R.H. C 1 10-24 x 1-1/4 Socket-Head Cap Screw 14 1 618L-1515Heater Head Assembly–208/240 Volt D 2 10-16 x 7/8 Hex Washer-Head Tek Screw 240 (See Figure B-3) 1 618L-1045 Heater Head Assembly–208/240 Volt, E 2 10-16 x 5/8 Hex Washer-Head Tek Screw CSA and Export (See Figure B-3) 1 618L...

Other models in this manual:
Fryers - 618L (1.46 mb)
Fryers - 618L (1.46 mb)
Fryers - 624 (1.46 mb)
Fryers - 624 (1.46 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category