Login:
Votes - 2, Average rating: 5 ( )

User manual Emerson, model UWL

Manafacture: Emerson
File size: 1.3 mb
File name: a6e65f2f-a28a-4861-ba66-7eacbd464bfc.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


Make sure that all electrical wiring and connections conform to local codes. A standard 120-volt grounded electrical outlet is required under the sink for the faucet’s electrical power. The wall outlet powering the tank must have electrical power supplied to it continuously. This outlet must be fused and should not be controlled by the same wall switch that operates a food waste disposer, unless you have a SinkTop Switch™ from InSinkErator®. It is recommended that a dedicated control valve be installed on the cold water line supplying water to this system. If you suspect elevated levels of chlorine in your water, it is recommended to use our water filtration system. The use of a water filter should NOT result in the water pressure to drop below 30 psi (207kPa). If it does, this will prevent your unit from operating properly. Moving parts inside the tank causing a rattling noise is normal. Equipment Required: Drill T-fitting Dedicated control valve Adjustable wrench Phillips and flat blade screwdrivers Pencil Tape measure Level WHAT YOU NEED TO GET STARTED Equipment You May Need: Anchors for drywall Basin wrench Hole saw Hole punch If you intend to use the sprayer hole in your sink for your faucet, you may need a basin wrench and a 1/8" plug or a 1/4" cap (not supplied) for the faucet spray hose line. See Step 1-B. If you need to cut a mounting hole in your stainless steel sink, you may need a 11.4" - 11.2" hole saw made for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than stainless steel. COMPONENTS IN THIS PACKAGE Lock Washer Hex Nut Deck Plate Metal 3/4" Screws (2) Snap-Connect UW/UWL Plastic Mounting Gasket Mounting Plate Fitting (3 pieces) Tank A 2 3 2 3 Unpack faucet components. On a firm, flat surface, carefully straighten the copper tubing. 1 Property Damage: Do not pinch or break copper tubing. Do not distort the last 1 inch of tubing. HOW TO USE THIS INSTRUCTION MANUAL These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process. What you’ll see in the INSTALLING THE FAUCET instruction manual: Provides a step-by-step narrative describing the installation step, with check boxes that can be marked as you progress through the installation. Contains simple illustrations that provide visual instruction to support the narrative. CAUTIONS, WARNINGS and DANGERS that will require your attention during the step. 1 2 3 An imminently hazardous situation, which, if not avoided, will result in death or serious injury. A potentially hazardous situation, which, if not avoided, could result in death or serious injury. A potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. A minimum of 2" Note: Tank must be located within 16" of faucet and within 30" or less of a standard grounded outlet. DO NOT extend plumbing or electrical lines. A standard 120-volt grounded electrical outlet is required under the sink for the unit’s electrical power. 2" of space is required from the center of the faucet head to the back wall in order for this appliance to operate properly. 3 START HERE PROPER INSTALLATION SHOULD TAKE ABOUT 2-4 HOURS PREPARATION Identify locations for the faucet and tank. 1 A Required minimum from center of hole to wall 2" Maximum counter thickness (depth) 11.2" Check to make sure there is proper clearance for faucet handle to be fully opened. Check to make sure counter is not too thick. Make sure there is a grounded electrical outlet under the sink. The wall outlet for your faucet must have power supplied to it continuously and must be fused. It should not be controlled by the same wall switch that operates a food waste disposer. B Turn off water supply. If using the sink sprayer hose hole, remove nut that connects sprayer hose at bottom of faucet. Using adjustable wrench, remove nut connecting sprayer washer flange in sprayer hole. Plug hose opening with either a 1/8" plug or a 1/4" cap (not supplied). If you have to drill through sink or countertop, you may need to rent or purchase the appropriate tools. C Required Hole Diameter 11.4" - 11.2" What if you don’t have a sprayer hole or don’t want to use it? Many homeowners replace the soap dispenser in their sink with an instant hot water dispenser. If drilling a hole into a stainless steel sink or counter top, you can cut a mounting hole for the faucet with a hole saw for stainless steel, or you can use a hole punch. Consult a professional before drilling into a surface other than stainless steel. Deck Plate Mounting Gasket Property Damage: Do not pinch or break copper tubing. Do not distort the last 1 inch of tubing. Unpack faucet components. On a firm, flat surface, carefully straighten the copper tubing. A C D INST...

Other models in this manual:
Water Dispensers - UW (1.3 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category