Login:
Votes - 1, Average rating: 5 ( )

User manual Accusplit, model AE760M100

Manafacture: Accusplit
File size: 368.23 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Whenever the stopwatch stops running, the "STOP" indicator will be ON. Press the button [START/STOP] to start the stopwatch. As it runs, the current elapsed time is shown on the lower line. {000} 0: 00' 00" 00 SPLIT 0: 00' 00" 00 LAP RUN 0: 03' 35" 52 To view the current split / lap time, you can press [LAP/SPLIT]. {001} 0: 10' 43" 35 SPLIT 0: 10' 43" 35 LAP RUN 0: 10' 43" 35 The number of split/lap times is shown on the upper left corner. The corresponding split and lap times are displayed on the upper and middle line. Press [LAP/SPLIT] again, the next split/lap time will be shown and the number of split/lap time is updated. {002} 0: 15' 10" 94 SPLIT 0: 04' 27" 59 LAP RUN 0: 15' 10" 94 The stopwatch (Model 790M & 790MDEC) can store up to 500 split / lap times. The split/lap times can be stored into the memory as you press [LAP/SPLIT] to view the current split/lap time. Meanwhile, the lap and split time will be frozen for 5 seconds. After this 5-second period, the lap and split time will return to normal. In addition, the fastest lap, the slowest lap, and the averages of all laps will also be recorded. As you press [STOP] to stop the chronograph, the last lap/split time will also be stored (provided that the last lap/split time is not the first lap/split time). When there are 5 free memories left, the icon "FULL" will blink to remind you of the nearly full situation. Whenever the storage is full, extra split/lap times will not be stored into memory but will still be shown on the display. Any fastest and slowest laps will not be stored. The memory counter will flash as the extra split/lap times are being displayed. The icon "FULL" will be steadily ON. The maximum memory counter value is 100 or 500. To stop the chronograph, press [STOP]. The indicator "STOP" will come on again to show the status. Press [RESET] as the stopwatch stops to reset the stopwatch while the split/lap times will be kept in memory. When the stopwatch starts running from reset state, all the lap memories will be cleared. Decimal Timing (AE790M500DEC model only) 1. The DM Model can operate as a normal 1/100 second chronograph as well as decimal minute, decimal second, and decimal hour chronograph. As you press [MODE] to enter the chronograph mode, the normal 1/100 second chronograph display will be shown. {000} 0: 00' 00" 00 SPLIT 0: 00' 00" 00 LAP STOP 0: 00' 00" 00 Reset the chronograph to 00, then press [LAP/SPLIT] to go to the second chronograph mode. (1/100s).You will note the change by looking at the bottom of the display to see 1/100s. {000} 0 0 0 0 0. 0 0 SPLIT 0 0 0 0 0. 0 0 LAP STOP 0 0 0 0 0. 0 0 1/100S Change to the 1/1000 of a minute chronograph mode by pressing [LAP/SPLIT] again. (1/1000M) {000} 0 0 0. 0 0 0 SPLIT 0 0 0. 0 0 0 LAP STOP 0 0 0. 0 0 0 1/1000M Go to the 1/10,000 hour chronograph by pressing [LAP/SPLIT] again.(1/10,000H) {000} 0. 0 0 0 0 0 SPLIT 0. 0 0 0 0 0 LAP STOP 0. 0 0 0 0 0 1/100000H Please note that if the stopwatch has started running (or is running), no selection for chronograph operating modes can be made until the stopwatch has been stopped and reset. Segmented run memory for lap/split time storage: A header consisting of the date/time stamp is attached to each segment to indicate the moment when you began recording the particular timing segment. To get to this feature, press [MODE] in chronograph mode to enter DATA mode when the stopwatch has been stopped. Records for different segments can be recalled, read or deleted. Detailed operation in "DATA" mode is described in Data Mode section below.. Chronograph Data Recall Mode Press [RECALL] in Chronograph mode to recall stored split/lap time memories. The mode message will be shown up for one to two seconds as mode message display is enabled. RECALL The split and lap time will be displayed on the upper and the middle line respectively. The lower line shows the current stopwatch counting. During data recall, the fastest lap time will be reviewed first. RECALL FAST {004} 0: 01' 12" 34 SPLIT 0: 00' 01" 60 LAP RUN 0: 03' 06" 52 Then comes the slowest lap time by further pressing of [RECALL]. RECALL SLOW {001} 0: 00' 07" 63 SPLIT 0: 00' 07" 63 LAP RUN 0: 03' 10" 16 Press [RECALL] again to view the average lap time. RECALL AVG {005} 0: 00' 05" 12 LAP RUN 0: 03' 16" 03 Press [RECALL] continually to review all the stored split/lap times. The sequence starts from the last record to the first record when the stopwatch is running and vice versa when the stopwatch has been stopped. RECALL {005} 0: 00' 14" 91 SPLIT 0: 00' 02" 05 LAP RUN 0: 03' 28" 94 [RECALL] RECALL {004} 0: 00' 12" 86 SPLIT 0: 00' 01" 60 LAP RUN 0: 03' 33" 64 [RECALL] RECALL {003} 0: 00' 11" 26 SPLIT 0: 00' 01" 78 LAP RUN 0: 03' 40" 15 [RECALL] RECALL {002} 0: 00' 09" 48 SPLIT 0: 00' 01" 85 LAP RUN 0: 03' 45" 34 [RECALL] RECALL {001} 0: 00' 07" 63 SPLIT 0: 00' 07" 63 LAP RUN 0: 03' 48" 01 After recalling the first record, press [RECALL] once more to exit from Recall mode and go back to chronograph m...

Other models in this manual:
Watches - AE602M100 (368.23 kb)
Watches - AE790M500 (368.23 kb)
Watches - AE790M500DEC (368.23 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category