manual abstract
If door is not completely closed, turn travel knob 1/4 turn “more”. Repeat as necessary. NOTE: 1/4 turn equals 1” of door travel. 20 Setting Door Opening Travel OPEN CLOSE MORE LESS MORE TRAVEL ADJUSTMENT Bottom Of Opener Tools Needed: Flat Tip Screwdriver The door opener is assembled with the open travel adjustment preset for a typical door, but all doors should be adjusted to stop as close as possible to the door’s “natural” fully open, resting position. To determine the door’s “natural” fully open, resting position, disconnect door from opener using the emergency release disconnect (see page 27, EMERGENCY DISCONNECT) and manually raise door to its “natural” fully open, resting position. Use this location for your open limit setting. To determine if door needs adjustment, activate the opener to bring door to fully open position. Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at Setting Door Opening Travel (Continued) Opener Trolley Stop Bolt NOTE: If door does not open fully and opener light flashes (make sure the bulb is installed and operating) check for an obstruction or see Adjustment #1, page 32 (Adjusting Opening Force). To adjust for a non-standard door or to precisely set the open position: Using the wall station, operate the door and stop it in mid-travel position. Using a flathead screwdriver turn the OPEN travel adjuster for more (counter-clockwise) or less (clockwise) travel. A 1/4 turn equals approximately 1” of trolley movement. NOTE: Confirm that the door has stopped in the UP position as a result of the upper limit switch and not because the trolley has hit the stop bolt, which is mounted in the rail near the opener. The correct condition can be verified by observing that the openers convenience light does not flash after the fully open door comes to a stop. The faulty condition may also be confirmed visually by checking to see if the trolley is resting against the stop bolt. To confirm final OPEN travel adjustment, activate the opener to bring door to fully open position. The opener light should not be flashing. Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at 21 Contact Obstruction Test 2 x 4 Laid Flat On The Floor Tools Needed: 2 x 4 Board After installing the opener, the door must reverse when it contacts a 1 1/2” inch high object (or a 2 x 4 board laid flat) on the garage floor. Using the wall station, activate the door to the fully open position. Place a 2 x 4 flat on the garage floor, under the door path. Activate the door to the closed position with the wall station. Upon contacting the 2 x 4 board, the door should reverse. If door stops on the 2 x 4 board, adjust the close travel knob 1/8-1/4 turn “more” until door reverses upon contact with 2 x 4 board. When the door reverses, remove the 2 x 4 board and run the full cycle of open and close of the door. Door should not reverse when it comes to the fully closed position on the floor. NOTE: If opener fails to pass this test, repeat Step 19. Also see Adjustment #2, page 32 (Contact Obstruction Test). IF OPENER DOES NOT RESPOND PROPERLY TO THESE TESTS (STEPS 21 AND 22), HAVE A QUALIFIED SERVICE PERSON MAKE NECESSARY ADJUSTMENTS/REPAIRS, OR SEVERE OR FATAL INJURY COULD RESULT FROM OPERATING THE DOOR/OPENER. WARNING 22Safety Sensor Obstruction Test Sensor 12” Sensor 12”6” Tools Needed: 2” x 6” x 12” Solid Test Object WHEN PERFORMING THIS PART OF THE TEST, DO NOT PLACE YOURSELF UNDER DESCENDING DOOR, OR SEVERE OR FATAL INJURY MAY RESULT. Starting with the door fully open, place a 6” high object on the floor, in line with sensors, 12” from the left side of the door. Activation of the opener with the wall station Up/Down button should cause the door to move no more than one foot, stop and then reverse to fully open position. Repeat this test with the 6” high object placed at the center of the door and then 12” from the right side of the door. The 6” high object, when placed on the floor in line with sensors, while door is closing, should also cause the door to reverse. WARNING IF OPENER DOES NOT RESPOND PROPERLY TO THESE TESTS (STEPS 21 AND 22), HAVE A QUALIFIED SERVICE PERSON MAKE NECESSARY ADJUSTMENTS/REPAIRS, OR SEVERE OR FATAL INJURY COULD RESULT FROM OPERATING THE DOOR/OPENER. WARNING Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at 23 Programming Wireless Keyless Entry (If Included) FORCE ADJ. STATUS SWPROGRAM Program Status LED...
Other models in this manual:Safety Gate - PRODRIVE 3220C (4.85 mb)
Safety Gate - PRODRIVE 3220C-Z (4.85 mb)
Safety Gate - PRODRIVE 3221C (4.85 mb)
Safety Gate - PRODRIVE 3221C-Z (4.85 mb)