• Open garage door using wall console. – Place a 2" x 4" board (laid flat) under center of garage door opening (Fig. 6-2). • Close garage door using wall console. • When door contacts board, the door must stop (within 2 seconds) and reverse direction returning to open position. 2. Adjustment. • If the door: – Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit. – Stops after contacting the 2 x 4 board and does not reverse, it may need an adjustment to the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit. • Test again. Repeat as necessary until door reverses upon contacting board. FIG. 6-2 2 x 4 under center of door opening ©2010 The Genie Company 12/2010 NOTICE IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE TO RELEASE CARRIAGE: 1. Pull handle DOWN then let go. 2. Manually move door until carriage releases from bullet. 3. Raise or lower door manually. DOOR PULL TO RECONNECT CARRIAGE: 1. Verify RED block is in the UP position. 2. Manually move door until carriage engages bullet. 3. Raise or lower door using remote or wall console. Release Handle ENGAGE DISENGAGE (for installation) TO REENGAGE PULL DOWN AND TOWARD POWERHEAD THEN LET GO (for installation) TO DISENGAGE PULL DOWN AND TOWARDS DOOR THEN LET GO DOOR TO RELEASE or RECONNECT CARRIAGE, PULL DOWN AND LET GO FIG. 6-4 Carriage Release (cut away view) CARRIAGE ENGAGE/DISENGAGE Use Release Handle to manually connect or release chain or belt bullet to Carriage. FIG. 6-3 Carriage Release CHANGE LIGHT BULBS WARNING • Observe all safety warning and precautions! Improper light bulb removal or replacement could result in Death or Serious Injury. • Disconnect power from opener before beginning this task. • When replacing light cover, make sure wires are not pinched or near moving parts. 1. Disconnect power to door opener. • Open powerhead light cover. • Remove light bulb(s). • Replace with maximum 100 Watt light bulb(s). – Do NOT use light bulbs with greater than 100 Watt rating. • Close powerhead light cover. 2. Reconnect power to door opener. • Test light operation. ©2010 The Genie Company 12/2010 19 RESET - OPEN/CLOSE TRAVEL LIMIT Performing all ten (10) Limits/Force setting steps (pages 6-7) erases previous Limits/Force settings. NOTE: The opener will not close the door automatically unless the Safe-T-Beam® System is installed and Limits are programmed. MOTION DETECTOR* - OVERVIEW (Not available on all models) Powerheads equipped with a motion detector sensor provide additional security when exiting or entering the garage area. *This sensor works by detecting body heat. Range of detection may be reduced when the temperature in the garage is close to body temperature. NOTE: Detector positioning on the powerhead provides for monitoring below the powerhead. OPERATION • Detector sensor is always ON. There are NO user controls or adjustments. • Lights automatically turn ON when a change is detected and will turn OFF after 4 minutes of no change. • Motion detector sensor will not turn OFF lighting turned ON at the wall console. • Lighting turned ON at the wall console will remain ON until wall console turns lighting OFF or opener is used. Motion Detector 20 ©2010 The Genie Company 12/2010 Independent Light Control Button Controls door opener lights from inside garage Sure-Lock™ Button – LOCK disables controls after door is completely closed – UNLOCK allows controls to work normally Indicator Light Red indicator light is always ON When Sure-Lock™ is ON the indicator light flashes Open/Close Button Open and closes door from inside garage WALL CONSOLE - OVERVIEW Use only the Series III wall console provided with this unit. Wall console has three buttons and one indicator light. Indicator Light Indicator light will display Red when wall console is properly wired and Sure-Lock™ is OFF. When Sure- Lock™ is ON indicator light flashes. Open/Close Button Use this button to open or close garage door. When Sure-Lock™ is ON the Open/Close button will CLOSE door only. Note: Constant button pressure in the CLOSE mode will override error responses in the powerhead and close door. Independent Light Control Button Use this button to turn powerhead lights ON. Powerhead lighting will remain ON until this button is pressed again or a door action has been completed. Note: If opener has a Motion Detector sensor the sensor will keep powerhead lights ON as long as motion is detected. Sure-Lock™ Button When Sure-Lock™ is ON the powerhead cannot be activated by the wall console or a remote. • Press and hold for 5 seconds (or until Indicator Light flashes) to activate Sure-Lock™. • Press and release to turn Sure-Lock™ OFF. OPTIONAL DUAL WALL CONSOLE - INSTALLATION Use only a Series III wall console when adding a second wall console. The optional second Genie® Series III wall console must be purchased separately. OR STB BWC IWC NOT USED N...

Other models in this manual:
Safety Gate - INTELLIG 4024 (11.33 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category